3 Final assembly and installation of oneAdvanced 10–14 PE
3.4.4
Inserting the installation kit into the tank
The preassembled Klaro E Professional installation kit is mounted on the dividing baffle. Aeration must
extend directly down to the tank base. Make sure that the disc aerator is aligned horizontally at the centre
of the chamber. You may have to readjust the disc by turning the horizontal pipe accordingly.
The sampling container must be filled with water. The weight of the filled sampler suppresses the installa-
tion kit's buoyancy, so it doesn't need to be additionally secured.
Outlet
Inlet
SBR reactor
Preliminary cleaning/sludge
storage tank