5 Assembling the switch cabinet for indoor installation
5
Assembling the switch cabinet for indoor installation
5.1
Selecting the location
When selecting the location for the switch cabinet, the following must be taken into
account:
-
-
Location
Cabinet
-
-
-
5.2
PP switch cabinet for indoor installation
5.2.1
Technical data
Version:
IP20
Material:
PP
Colour:
black
Closure:
Screw locking at the centre of the front side
Electrical connection:
Onsite backup fusing required
1~230 V, 50 Hz
Connections to the switch cabinet:
Compressed air connectors:
3 x 13 mm, 1 x 19 mm
Connecting line with E+F type plug
Height above the highest water level in the tank in order to avoid overflow and
water intake in the open channel in the event of an accident.
The system generates noise! When operating, the air compressor generates
continuous noise comparable to an oil heating fan or freezer.
The control requires a protected electrical connection. The electrical connec-
tion serves as a mains disconnecting device and must be easily accessible at
all times. Additional electrical fixtures on the same fuse may disrupt operation.
The location of the machine cabinet must be a dry, cool and well-ventilated
room. The cabinet, in particular the ventilation openings, must not be covered
and must be freely accessible for maintenance work.
The air hoses must be no longer than 20 metres.
280
420
PP cabinet measurements