3 lines for inserting the operators' names;
-
a keypad for setting characters.
To save the set data, select the Save button
.
To quit the programme, select the Exit button
.
Note
Each line for storing the workshop data consists
of a maximum of 28 characters.
Each line for storing the operators' names con-
sists of a maximum of 14 characters.
Note: If connected to a printer, the stored cus-
tomisation data will be printed in the relative
reports.
6.2. Wheel balancer parameter configuration
Modifications to factory settings normally are not
required. However, if necessary, the machine sta-
tus and/or the operating mode can be modified.
Each parameter can be modified using the arrow
keys
.
The parameters that can be modified are:
1. Language:
-
to set the preferred language
2. Timeout screensaver:
-
to set the waiting time before the main logo is
displayed
3. Radial runout threshold (1st harmonic):
-
to set the threshold that displays the measured
value in red
4. Radial runout threshold peak-to-peak:
-
to set the threshold that displays the measured
value in red
5. Lateral runout threshold (1st harmonic):
-
to set the threshold that displays the measured
value in red
6. Lateral runout threshold peak-to-peak:
-
to set the threshold that displays the measured
value in red
7. WARNING RUNOUT:
-
enables automatic measurement of the radial
EM9980 TouchlessLine - Operator's manual
run-out of the wheel assembly or rim during
the measurement cycle (YES enabled – NO
disabled) The alarm indicator light is activated
automatically in the main working screen (YES
activated – NO deactivated)
8. OPT warning:
-
to display the alarm indicator light in the main
working screen (YES enabled – NO disabled)
9. Disable laser:
-
to disable the lasers when faulty. If disabled,
the dimensions must be set manually and the
weights applied in the 12 o'clock position
10. Automatic position search (RPA):
-
to enable automatic position search at the end
of the spin (YES enabled – NO disabled)
11. dimension measurement with C unlocking:
-
to set automatic dimension measurement every
time the automatic wheel clamping system is
activated (YES activated – NO deactivated).
12. enables/disables the rim search
-
for activating detection of ONLY the rim
mounted on the machine while measuring the
dimensions (YES activated – NO deactivated)
13. automatic light
-
to activate operation of the LED light as required
(YES activated – NO deactivated)
-
when the programme is active, the light is
enabled in the following cases:
-
during the entire measuring cycle, with the
exception of during dimension acquisition;
-
in CP (centred position) for an additional 30
seconds;
-
during the Hidden Weight programme when
selecting the two planes behind the spokes.
14. Set factory data:
-
to reset the initial machine configuration Ma-
chine calibrations are not modified.
To save the new settings, press the Save
button and press the Exit button
to go back to the main working screen.
6.3. Unbalance sensitivity calibration
This procedure should be performed whenever
calibration appears to be out of the tolerance range