NOTE: The information contained in this Manual is designed to assist you in the safe maintenance of the Nailer.
Some illustrations in this Manual may show details or attachments that diff er from those on your own Nailer.
MAINTENANCE AND INSPECTION
Read section titled "SAFETY" (pages 4 – 8).
● Disconnect air hose and remove all nails
from Nailer when:
1) doing maintenance and inspection; and
2) clearing a jam.
1. Clearing a jam
Remove a jammed nail in the following order:
1 DISCONNECT AIR HOSE.
2 Insert a rod into the outlet.
Tap the rod with a hammer.
Hammer
Rod
Outlet
3 Remove the jammed nail with a slotted screw
driver.
4 In case of frequent jam, contact a metabo HPT
authorized service center.
2. Inspecting the magazine
1 DISCONNECT AIR HOSE.
2 Clean the magazine. Remove plastic tips or
wooden tips which may have accumulated in
the magazine. Lubricate it with metabo HPT
pneumatic tool lubricant.
18
MAINTENANCE
WARNING
Disconnect
1
air hose
Nail Feeder
CAUTION
● Check that the nail feeder slides smoothly by
pulling it with fi nger.
If not smooth, nails can be driven at an irregular
angle and hurt someone.
3. Storing
○ When not in use for an extended period, apply a
thin coat of the lubricant to the steel parts to avoid
rust.
○ Do not store the Nailer in a cold weather
environment.
Keep the Nailer in a warm area.
○ When not in use, the Nailer should be stored in a
warm and dry place.
Keep out of reach children.
4. WARNING LABEL
Do not use the Nailer with missing or damaged
WARNING LABEL.
A new WARNING LABEL is available from a
metabo HPT authorized service center.
Magazine
Disconnect
1
air hose
Warning Label