3. Technical data
Designation
Description
General
Measurement channel
Display
Keyboard
Measuring range
Resolution
Measurement Bandwidth
Signal amplification
Audio
Amplification
Maximum output
Headset
Headset connector
Power
Battery
Battery life
Environmental
Operating temperature
IP rating
Mechanical
Housing material
Dimensions instrument
Flexible rod length
Weight instrument
Carrying case dimensions
Total weight (incl. case, sensor & 2 AA batteries)
4. Spare parts
Designation
TKSU 10-HEADS
TLGU 10-HANDS
TLGU 10-PROBE
TLGU 10-CRADLE
TLGU 10-CC
TDTC 1/C
SKF TLGU 10
Ultrasound lubrication checker
1 channel via a 7 pole LEMO connector
160 × 128 pixels Color OLED
5 function keys
-6 to 99.9 dBµV (reference 0 dB = 1 µV)
0.1 digit
35 to 42 kHz
+30 to +102 by step of 6 dB
5 adjustable positions in steps of 6 dB
+83 dB SPL with supplied headset
25 dB NRR Peltor HQ headset
Stereo jack connector of 6.35 mm (1/4 in)
2 AA batteries; rechargeable batteries too
7 hours
from –10 °C to +50 °C (14 °F to 122 °F)
IP42
ABS
158 × 59 × 38.5 mm (6.22 × 2.32 × 1.51 in)
445 mm (17.51 in)
164 g (5.78 lb)
530 × 110 × 360 mm (20.9 × 4.3 × 14.2 in)
3 kg (6.6 lb)
Description
Neckband headset for TLGU 10 and cable
Ultrasonic Lubrication Checker handset
Probe and accessories: coiled cable, grease gun adapter,
SKF grease gun thread adapter, 2 magnetic bases
Grease gun mounting strap and magnetic cradle
Toolcase with inlay for TLGU 10
General toolcase without inlay, size C
9
EN

Publicidad

loading