Setting temperature limiter
Prod. no. 36 211 and 36 237
1. Unscrew screw (E) with 2mm hexagon key, see Fig. [5].
2. Turn mixing lever (F) clockwise until desired temperature is
reached.
3. Pull off mixing lever (F), see Fig. [6].
4. Pull off stop ring (G) and push on again with notch (G1)
vertical to top.
5. Turn mixing spindle (H) counterclockwise to the stop.
6. Push on mixing lever (F) horizontally and secure with
screw (E).
Prod. no. 36 227
1. Unscrew screw (I) with 2mm hexagon key, see Fig. [7].
2. Pull off stop ring (J)
3. Turn mixing spindle (K) clockwise by using a screw driver
until desired temperature is reached.
4. Push on stop ring (J) again and secure with screw (I).
Cleaning
For cleaning purposes the faucet can be switched off by
mounting the enclosed cleaning clip (L), see Fig. [8].
With remote control (see special accessory, ref.-no.: 36 206)
the faucet can be switched off.
Automatic safety stop
After 60 s (factory setting) of continously entry of an object
the infrared electronics will stop the water course
automatically.
With remote control (see special accessory, ref.-no.: 36 206)
the safety stop is adjustable in levels from 2 - 420 s.
English
Automatic flushing
The automatic flushing serves to protect the water hygiene in
cases of longer non utilization the faucet and activates water
flow 1 or 3 days after the last use for 1 - 10 minutes.
Safety notes:
- Guarantee free drain in the case of activated automatic
flushing.
- For the execution of the automatic flushing of the cold and
hot water line the faucet must be in mixed water position.
With remote control (see special accessory, ref.-no.: 36 206)
the automatic flushing can be activated and setted.
1. Switch automatic flushing On / Off.
x
Press and hold key RESET.
x
Pressing key OFF AUTO within 2 s.
(Control light in the sensor flushes).
- Switch on: pressing key OFF AUTO within 10 s
Control light in the sensor flushes 4 x short = On
- Switch off: pressing key OFF AUTO within 10 s
Control light in the sensor flushes 2 x long = Off
Leaving the adjusting mode automatically after 10 s.
2. Change flushing interval from 3 to 1 day
(setting-up: 3 days).
x
Press key TEST.
With the key ON AUTO the flushing interval can be setted.
x
Press key ON AUTO.
Control light in the sensor flushes:
- 2 x long = 1 day
- 4 x short = 3 days
Leaving the adjusting mode by pressing key TEST or
automatically after 60 s.
3. Set flushing period from 1 to 10 minutes
(setting-up: 5 minutes).
x
Press key TEST.
With the keys + and - (key
be increased (+) or decreased (-).
x
Press key + or - (key
Control light in the sensor flushes:
- 4 x short = shift one step (approx. 1 minute)
- 2 x long = achieve the end position
Leaving the adjusting mode by pressing key TEST or
automatically after 60 s.
(factory setting: Not activated)
) the flushing period can
).
2

Publicidad

loading

Este manual también es adecuado para:

Europlus e 36 212Europlus e 36 227Europlus e 36 237