Error number
Cause
F0003
HP pump 1 connection. No CAN bus data connectionHP pump 1
F0004
HP pump 1 overload. Output overload HP pump 1
F0005
Remote control 1 connection. No CAN bus data connection Remote control 1
F0063
A39 connection. No CAN bus data connection
F0064
A39 overload. Output overload A39
F0065
A40 connection. No CAN bus data connection
F0066
A40 overload. Output overload A40
F0101
Exterior temp sensor defective
F0170
HP pump 1 overcurrent. Current consumption of HP pump 1 too high.
F0171
HP pump 1 minimum current. Current consumption of HP pump 1 too low
F0172
Relay / HP pump 1 contactor stuck. HP pump 1 electronics malfunction
F0174
HP pump 1 winding protect.contact
F0175
HP pump 1 overpressure
F0176
HP pump 1 oil level too low
F0190
Coin reset remote control 1
F0191
Coin signal remote control 1
F0570
Hot water shortage
F0571
Hot water overtemperature
F0572
Hot water temperature sensor defective
F0576
No flow detected by flow monitor
F0577
Flow monitor is defective
F0578
Automatic hot water circuit-breaker
F0610
BA regeneration failed. Hardness sensor indicateshard water after regeneration.
F0611
BA regeneration failed. Regeneration of the bottle could not be started.
F0612
Permeate buffer tank dry running. Have the tank filled up to the empty buffer tank level switch
(maximum switch-on delay of 15 minutes)
F0613
Permeate buffer tank level switch. Empty and full buffer tank level switches switch simultaneously
F0614
Permeate buffer tank level switch. Empty and full buffer tank level switches switch simultaneously
F0615
Water softening no water pressure
F0616
On-site water treatment system
F1125
Controller Batterie Back-Up Batterie Of Controller Defective
Malfunction
Possible cause
System does not come up
Water supply volume too low.
to pressure or the pump
High-pressure nozzle clogged or
knocks
rinsed out.
Incorrect high-pressure nozzle in-
stalled.
Line clogged.
System draws in air.
High-pressure pump leak-
Defective pump component.
ing (more than 3 drops of
water per minute)
Detergent not being
Clogged filter or clogged hose.
sucked
Defective check valve.
Pump hose in the dosing pump dam-
aged.
High-pressure pump
Detergent container empty.
sucking air
Malfunction
Possible cause
Water shortage in the hot
Water inlet blocked.
water float tank
Float valve defective.
Dry running sensor defective.
Hose burst or released.
System disconnection pump (optional)
not working.
Water temperature too
Hot water temperature sensor is defec-
high or too low
tive.
Malfunction
Possible cause
The coin acceptor rejects
Trigger switched off.
all coins
Time or operating times incorrectly set. Check the settings at the control.
A critical fault has deactivated the system. Check the control for critical faults. Rectify and acknowledge possible faults.
The coin acceptor is soiled.
28
Malfunctions indicated by the control
Faults that are not displayed
Malfunctions at the high-pressure pump
Rectification
Check the water supply volume (see the Technical data).
Clean or replace the high-pressure nozzle.
Replace the high-pressure nozzle (for size see "Technical data").
Check that all lines are free.
Check the system for leaks, detergent suction hose must be inserted into the de-
tergent, refill the detergent container.
Check the pump hose for cracks and wear and replace if necessary.
Replace the defective component.
Clean the parts.
Replace the valve.
Check the pump hose for cracks and wear and replace if necessary.
Fill with detergent.
Malfunctions at the hot water generation
Rectification
Open the fresh water stop valve (on site).
Check the float valve, repair it if necessary
Check the sensor.
Check hose lines, fasten or replace if necessary.
Check the pump. Check the power supply of the pump.
Check the temperature sensor, replace it if necessary.
Coin slot malfunctions
Rectification
Turn the trigger (in the device) to "1".
Clean the coin slot (see "Care and maintenance").
English
Rectification
Inform Service
Inform Service
Inform Service
Inform Service
Inform Service
Inform Service
Inform Service
Inform Service
Ackowledge fault. Inform Service if fault occurs
again.
Inform Service
Inform Service
Ackowledge fault. Inform Service if fault occurs
again.
Ackowledge fault. Inform Service if fault occurs
again.
Refill oil, Acknowledge malfunction
Inform Service
At mechanical coin acceptor check the mi-
croswitch
Check the hot water supply
Ackowledge fault. Inform Service if fault occurs
again.
Inform Service
Ackowledge fault. Inform Service if fault occurs
again.
Ackowledge fault. Inform Service if fault occurs again.
Reset automatic circuit-breaker
Refill salt, acknowledge fault
Inform Service
Have the tank filled up to the empty buffer tank
level switch (maximum switch-on delay of 15
minutes)
check level switch.
check level switch.
Check the water supply
Check on-site water treatment system
Inform Service
By whom
Operator
Operator
Operator
Operator
Operator
Operator
Customer Service
Operator
Customer Service
Operator, Customer
Service
Operator
By whom
Operator
Operator
Operator
Operator
Customer Service
Customer Service
By whom
Operator
Operator
Operator
Operator