The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage and rated
current.
If static pressures exceed 0.5 MPa, a pressure-reducing valve
must be installed.
Avoid major pressure differences between hot and cold water
supply!
Operation and settings,
see technical product information 99.0438.xxx
Activating setting mode
Disconnect the power supply to the electronics and reconnect
after 10 s.
Fault/Cause/Remedy
Fault
Water not flowing
Undesired water
flow
Flow rate too low
CN
CE
29
Cause
• Filter upstream of solenoid valve blocked
• Solenoid valve defective
• Plug-in connector without contact
• No voltage
- Battery discharged
(indicator lamp lights up continuously)
- Power supply unit defective
• Sensor system detection zone set too high
for local conditions
• Automatic flushing activated
• Solenoid valve defective
• Mousseur dirty
• Filter upstream of solenoid valve dirty
• Filters in connection hose dirty
• Non-return valve defective
The indicator lamp in the sensor system illuminates in setting
mode when the detection zone of the fitting is reached by an
approaching user.
Setting mode is automatically terminated after 3 minutes.
Maintenance
Batteries which are almost discharged are displayed
by a flashing indicator lamp in the sensor system.
Replacement parts
see front page (* = special accessories)
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
This product must be installed in conformance with local codes
e.g. AS/NZS 3500 series of standard!
Remedy
- Clean filter
- Replace solenoid valve
- Check plug-in connector electronics and solenoid
valve
- Replace battery
- Replace power supply unit
- Reduce range using remote control (special
accessory, prod. no.: 36 407) / app
- Wait 1 - 10 minutes
- Replace solenoid valve
- Clean or replace mousseur
- Clean filter
- Clean or replace filters
- Replace the non-return valve
6 - 420
34
100-240 V AC 50-60 Hz/6.75 V DC
6V
CR-P2
2.4 W
60