Störung
Ursache
Wassermenge zu
• Mousseur verschmutzt
gering
• Sieb vor Magnetventil verschmutzt
• Siebe in Anschlussschläuchen verschmutzt
• Rückflussverhinderer defekt
GB
Safety notes
Prevent danger resulting from damaged voltage
supply cables.
If damaged, the voltage supply cable must be replaced
by the manufacturer or his customer service
department or an equally qualified person.
• Installation is only possible in frost-free rooms.
• The plug-in voltage supply is only suitable for indoor use.
• The plug-in connectors must not be directly or indirectly
sprayed with water when cleaning.
• The voltage supply must be separately switchable.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and the CE identification, and could lead to injuries.
Battery information
Use the batteries supplied as standard for the initial start-up.
Ensure polarity is correct when inserting batteries! Only use
batteries of the same type. Always replace all batteries at the
same time, do not mix new and used batteries together. Do not
recharge used batteries, and do not attempt to reactivate them
using heat or other means. Rechargeable batteries may not be
used. Discharged batteries must be removed from the device
immediately, increased risk of leakage!
Technical data
Fitting with switched-mode power supply:
• Voltage supply:
• Power consumption:
Fitting with battery:
• Voltage supply:
• Automatic safety shut-off:
(6 - 420 s adjustable)
• Run-on time (0 - 19 s adjustable):
• Reception range according to Novoflex Zebra XL Grey Card,
grey side, 8x10", landscape (7 - 20 cm adjustable):
• Type of fitting protection:
Fault / Cause / Remedy
Fault
Cause
Water not flowing
• Filter upstream of solenoid valve blocked
• Solenoid valve defective
• Plug-in connector without contact
• No voltage
100-240 V AC 50-60 Hz/6.75 V DC
6V lithium battery type CR-P2
- Battery discharged
(indicator lamp lights up continuously)
- Power supply unit defective
Abhilfe
- Mousseur reinigen oder austauschen
- Sieb reinigen
- Siebe reinigen oder austauschen
- Rückflussverhinderer austauschen
Thermal disinfection possible.
Electrical test data
• Software class
• Contamination class
• Rated surge voltage
• Temperature of ball impact test
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage and rated
current.
If static pressures exceed 0.5 MPa, a pressure-reducing valve
must be installed.
Avoid major pressure differences between hot and cold water
supply!
Operation and settings,
see technical product information 99.0438.xxx
Activating setting mode
Disconnect the power supply to the electronics and reconnect
after 10 s.
The indicator lamp in the sensor system illuminates in setting
mode when the detection zone of the fitting is reached by an
approaching user.
Setting mode is automatically terminated after 3 minutes.
2.4 W
Maintenance
Batteries which are almost discharged are displayed
by a flashing indicator lamp in the sensor system.
60 s
Replacement parts
See front page (* = special accessories)
1 s
12 cm
Care
IP 59
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
Remedy
- Clean filter
- Replace solenoid valve
- Check plug-in connector electronics and solenoid
valve
- Replace battery
- Replace power supply unit
7
A
2
2500 V
100 °C