In order to generate the required humidity during incubation time, fill the basin
supplied with water and place it on the shelf next to the fan cage (ref. CIP CIP
28). Fill just the smaller basin through with water regarding model CIP CIP 40.
USE AND CALIBRATION
Plug the incubator into the electric power and allow it to come up to operating
temperature (100°F). Allow the machine to run at the correct temperature before
setting the eggs.
When the incubator has been running at the working temperature of 100°F, place
the eggs in the incubator lying on the wire mesh, between the rods of the egg
grid & esure that the peg on the turner motor on the underside of the incubator
top is inserted into the metal stirrup connected to the egg grid.
The thermostat, placed on the unit top, has been set-up by the facto-
ry and indicates when the machine is working (the led power results
lighted). The continuous or intermittent lighting of the led – ON – points
out the heating activation.
Check that the set temperature on the thermostat dial agrees with the
reading on the alcohol thermometer inside the incubator.
If necessary, adjust the set temperature slightly by using a screwdriver
in the central white screw on the thermostat box until the thermometer
reads 100°F (37,7°C). It's important to check the temperature on the
thermometer in the incubator.
: if all instrument setting attempts result useless, do not
important
remove absolutely the thermostat from its place to effect
any improper or not authorized operation, just contact the
builder for a possible reparation or substitution.
For the models equipped with FIEM MINILCD THERMOSTAT
1. Product overview
A
B
2. Key functions
Change mode display and change parameters
Setting temperature and humidity reference values
Change mode display and change parameters
+
+
3. Functionality description
MiniLCD is able to control with ON-OFF method or PID algorithm the temperature (see paragraph 7) and with mode
ON-OFF the incubation humidity.
At power on, a welcome message will appear briefly followed by firmware version of the board.
MiniLCD will prompt the current temperature and by pressing the arrow UP or DOWN the relative humidity.
By pressing the SET button you can modify the temperature and humidity value already set.
In case temperature or humidity probe fail, or in case one of them isn't connected, in the relative visual mode will
prompt ERR and the output will not controlled.
MiniLCD has in addition two different menus, one for the user, where you can customize the basic functions, and one
technical that permit to setup the machine and adjust the probe.
During start-up, menu for setting the type of temperature control.
12
D
G
C
E
Technical menu for the calibration parameters, measurement units
During start-up, menu for setting the type of temperature control
Fig. 2:
water basin
positioning
Fig. 3:
automatic
egg-turner
connection
F
A. Power switch
B. Light switch
C. 3 digits display with dot separation value
D. temperature LED
E. humidity LED
F. selection button <arrow up>
G. setting button
H
H. selection button <arrow down>
fig.1:
assamblage of the thermometer