First filling with sticker
Required oil volume: 9 litres (HLP 32) for system.
Lifts with this sticker already have hydraulic oil in the hy-
draulic cylinders and hoses.
After setting up the electrical connection to the lift, the
hydraulic system can be filled.
9
9 Operating lever
10 2 x Allen key operating lever
11 Oil filling opening
• Loosen and remove the plastic part of the operating le-
ver (9) of both Allen screws (10).
• Loosen and remove the unit cover.
• Unscrew the oil filling opening (11).
• Fill 9 litre hydraulic oil (HLP 32).
• Raise the lift approx. 1 m by pushing the operating le-
ver (9). The lift rails can be lifted at different times!
• Hang in the lifting arms and secure them.
• Push the operating lever forwards and raise the lift to its
uppermost end position.
• Push and hold the operating lever for another 60 sec-
onds so air can escape from the system and the over-
flow procedure equalises the lift to each other.
For first commissioning, it is normal to have
!
a different start up and a large "shaking" in
OPI-POWER LIFT HF 3S 3000-4000-V4.0-DE-EN-FR-ES-IT
the uppermost position. Air trapped in the
system must be completely removed first.
• Afterwards lower the lift to its lowest position. Pull the
operating lever (9) and hold it until the lifting arm is
completely lowered.
The oil level should be approx. 30 – 40 mm
!
below the oil fill opening. Do not fill the oil
tank up to the upper edge, as otherwise
during lowering the oil return line can pull
oil out of the line and afterwards result in a
very slow lifting at the upper range.
• After commissioning, the sticker (first filling) can be re-
moved.
First filling without sticker.
Required oil volume: 13 litres (HLP 32) for system, hoses
and cylinders.
• After setting up the electrical connection to the lift, the
hydraulic system can be filled.
• Loosen and remove the plastic part of the operating le-
ver (9) of both Allen screws (10).
10
• Loosen and remove the unit cover.
• Unscrew the oil filling opening (11).
• Fill hydraulic oil: 9 litre (HLP 32).
• Raise the lift approx. 1 m by pushing the operating lever
(9). The lift rails can be lifted at different times!
• Hang in the lifting arms and provide with safety rings.
• Push the operating lever (9) forwards and raise the lift
to its uppermost end position.
11
• Now fill the oil tank with hydraulic oil:
4 litre (HLP 32)!
• Afterwards hold the operating lever another 60 sec-
onds so air can escape from the system and the lift rails
can be equalised by the overflow procedure.
For first commissioning, it is normal to have
!
a different start up and a large "shaking" in
the uppermost position. Air trapped in the
system must be completely removed first.
• Afterwards lower the lift to its lowest position. Pull the
operating lever (9) and hold it until the lifting arm is
completely lowered.
The oil level should be approx. 30 – 40 mm
!
below the oil fill opening. Do not fill the oil
tank up to the upper edge, as otherwise
during lowering the oil return line can pull
oil out of the line and afterwards result in a
very slow lifting at the upper range.
105