Check electrical components for function and condition.
• Plug.
• Operating lever with button switch.
• During assembly and maintenance always check the condition of electrical
lines. All cables and lines must be secured so they cannot be crushed, kinked
or contact any moving assembly.
Optional energy set:
• Electrical socket
• Pneumatic connection
Check for condition and function.
Check the paint:
• Check the powder coating and improve if required.
Damage by external influences is to be treated immediately after detection.
If these points are not treated, infiltration of deposits of all kinds can cause
wide-ranging and permanent damage.
These points are to be lightly sanded (120 grit), cleaned and degreased.
Afterwards, rework with a suitable touch up paint (note the RAL No.).
• Check galvanised surfaces, touch up as needed.
White rust is fostered by permanent humidity, poor ventilation. The affected
areas can be treated by using a sanding cloth (A 280 grit). If required, the
parts are to be treated with a suitable, resistant material (paint etc.). Check
the RAL colour selection.
• Rust is brought out by mechanical damage, wear, aggressive deposits (de-ic-
ing salt, leaking operating fluids) cleaning that is not done or incomplete.
The affected areas can be treated by using a sanding cloth (A 280 grit). If
required, post-treat the areas with a resistant material (paint etc.).
According to manufacturer instructions, the hydraulic oil should be changed
every two years in normal operations. Various environmental influences e.g.
location, temperature swings, intensive operation etc, can have an influence on
the quality of the hydraulic oil. For this reason, the oil must be checked during
annual safety inspections and maintenance.
The oil is used if it has a milky colour or if the hydraulic oil smells unpleasantly.
To change oil, lower the lift is to its lowest position then suction the oil out of the
oil container and replace the contents.
The manufacturer recommends high-quality clean hydraulic oil. The required oil
volume and type is to be taken from the technical data. After filling (18), the
hydraulic oil must be between the upper and lower marking on the oil dipstick,
or approx. 2 cm below the oil filling opening. Dispose of the old oil according
to regulations to the intended location (district offices, environmental protection
office or commercial regulatory office has the obligation to disclose about dis-
posal points).