In order to achieve the test report results, please load the performance parameters retained
by the manufacturer and the qualifi ed technician. They will use these parameters once verifi ed
that, during the installation, it is possibile to reproduce the laboratory conditions.
Plumbing system connection
The connection of the stove to the plumbing system must be made ONLY
by specialized personnel who are capable of carrying out installation
properly, in compliance with current standards in the country of installation.
The manufacturer will not be held responsible for damage to persons or
things in the event of failed operation if the aforementioned warning is not
complied with. anti-condensation valve must be installed in the return fl ow. It is mandatory
to install an anti-condensate valve on the return of the system, set at 60 ° C. The valve
isn't a standard thermostove component and it isn't delivered with the thermostove.
Closed vessel system
This product has been designed and built to work with closed vessel systems. In general, the
closed vessel system has the following expansion as the expansion vessel pre-loaded. In addition
to the expansion device, the closed vessel system must be provided in accordance with current
Italian UNI 10412-2 (2009) by:
•
safety valve
•
thermostat control of the circulator
•
device alarm sounds
•
temperature Indicator
•
pressure indicator
•
audio alarm
•
automatic adjustment
•
safety thermostat with manual reset
•
circulation system
Connection diagram for thermostove equipped without kit
for domestic hot water production
A 2
WATER
RETURN
C
A1
WATER
The pressure relief valve (C) must always be
DELIVERY
connected to a water drain pipe. The tube must
be capable of withstanding high temperature
and pressure.
53