3.3
ACCESS TO
INSTALLER'S
5
PARAMETERS
For access to the installer's parameters,
press simultaneously the keys
3
or 2 seconds (3 fig. 12).
For example, the parameter PAR 23 is
1
visualised on the display of the control
panel in the following way:
2
4
5
5
5
The parameters scroll forwards and
backwards with the key
the default parameters can be changed
3
with the keys
and
The standard visualisation returns auto-
1
1
matically after 60 seconds, or by pres-
sing one of the control keys (2 fig. 12)
2
excluded the key RESET.
2
2
3.3.1
Replacing the board or
4
RESETTING parameters
If the electronic board is replaced or
reset, it is necessary to configure PAR 1
and PAR 2 by associating the following
values to each type of boiler to be able to
restart the boiler:
GAS
MODEL
220 BOX ErP
METHANE
330 BOX ErP
(G 20)
440 BOX ErP
550 BOX ErP
660 BOX ErP
220 BOX ErP
PROPANE
330 BOX ErP
(G 31)
440 BOX ErP
550 BOX ErP
660 BOX ErP
58
5
FAST CONFIGURATION
PAR DESCRIPTION
1
Combustion configuration
3
and
2
Hydraulic configuration
1
3
Timetable 2 programmer
2
4
Pressure transducer disabler
4
5
5
Assignment of auxiliary relay AUX
3
3
and
and
3
1
1
.
6
Luminous bar indicating presence
of voltage
7
Allocation of SIME HOME channels 0 = Not assigned
2
8
Fan rpm Step ignition
4
4
9
Long chimneys
10
Remote control option setting
4
11
Correction values external sensor
12
Backlighting duration
13
Modulating pump speed
PAR 1
14
Setting second input TA
69
15
Cascade address
16
ModBus address
17
ModBus communication configuration 1 ... 30
19
Type circuit
71
D.H.W. - HEATING
PAR DESCRIPTION
20
Minimum heating temperature Zone 1 PAR 64 OEM ... PAR 21
21
Maximum heating temperature Zone 1 PAR 20 ... PAR 65 OEM
22
Heating curve slope Zone 1
23
Minimum heating temperature Zone 2 PAR 64 OEM ... PAR 24
24
Maximum heating temperature Zone 2 PAR 23 ... PAR 65 OEM
25
Heating curve slope Zone 2
26
Minimum heating temperature Zone 3 PAR 64 OEM ... PAR 27
27
Maximum heating temperature Zone 3 PAR 26 ... PAR 65 OEM
28
Heating curve slope Zone 3
29
∆t heating circuit
30
Post-circulation heating time
31
Maximum heating capacity
32
Zone 1 pump activation delay
33
Start-up delay
34
Additional source activation threshold
35
Boiler antifreeze
36
External sensor antifreeze
37
Band saturation
flowmeter modulation
38
D.H.W. post-circulation time
39
Anti-legionella
(only D.H.W tank))
PARAMETERS INSTALLER
RANGE
MEASUREMENT
-- = ND
1 ... 63
-- = ND
1 ... 14
1 = DHW + Recirc. pump
2 = DHW
3 = Recirculation pump
0 = Disabled
1 = Enabled 0-4 BAR
2 = Enabled 0-6 BAR
3 = Enabled 0-4 BAR (NO ALL 09)
4 = Enabled 0-6 BAR (NO ALL 09)
1 = Remote supply
2 = Recirculation pump
3 = Automatic load.
4 = Remote alarm NC
5 = Heat pump
6 = Zone 2 valve
0 = Disabled
1 = Enabled
1 = Circuit 1
2 = Three-zone circuit
0,0 ... 81
0 ... 20
1 = SIME HOME
2 = CR 53
3 = RVS 43.143
4 = RVS 46.530
5 = RVS 61.843
-5 ... +5
-- = Always
0 = Never
1 ... 199
-- = None
Au = Automatic mod.
30...100 = % Settable
modulation
-- = Contact TA
5...160 = Input 0...10VDC
-- = Not enabled
0 = Master
1...7 = Slaves
-- = Not enabled
1...31 = Slaves
0 = Two zones
1 = Three zones
RANGE
MEASUREMENT
3 ... 40
3 ... 40
3 ... 40
10 ... 40
0 ... 199
30 ... 100
0 ... 199
0 ... 10
-- , -10 ... 40
0 ... +20
-5 ... +5
-- = Disabled
0 ... 100
0 ... 199
0 = Disabled
1 = Enabled
UNIT OF
INC/DEC
DEFAULT
UNIT
SETTING
=
=
"- -"
=
=
"- -"
=
=
1
=
=
1
=
=
1
=
=
1
=
=
1
rpmx100 0,1 from 0,1 to 19,9
0,0
1 from 20 to 81
%
1
0
=
=
1
°C
1
0
sec. x 10
1
3
%
10
Au
--
--
--
--
1
--
--
1
--
--
1
25
--
--
0
UNIT OF
INC/DEC
DEFAULT
UNIT
SETTING
°C
1
20
°C
1
80
--
1
20
°C
1
20
°C
1
80
--
1
20
°C
1
20
°C
1
80
--
1
20
°C
1
20
Sec.
10
30
%
1
100
10 sec.
1
1
Min.
1
3
°C
1
"- -"
°C
1
3
°C
1
-2
%
1
100
Sec.
1
0
--
--
0