1. GÉNÉRALITÉS • GENERAL • ALGEMEEN • GENERAL • GENERALE
3) Minimum continuous speed
Upon power-up, the unit runs at the minimum continuous speed settable from 0 to 47 m
- press the MENU button until the "A" (A) letter is displayed.
- press the buttons + or - to increase or decrease the minimum continuous speed between the values shown in the table below:
Minimum countinuous speed (A A )
m
/h
Display
3
0
A00
14 (default)
A14
22
A22
29
A29
36
A36
47
A47
4) Intermediate speed
The unit runs automatically at the intermediate speed settable from 22 to 90 m
have been met:
- the humidistat has been activated.
- the run-on timer has been activated.
The intermediate speed can be set in the following way:
- press the MENU button until the "b" (b) letter is displayed.
- press the buttons + or - to increase or decrease the intermediate speed between the values shown in the table below:
Intermediate speed (b b )
m
/h
Display
3
22
b22
29
b29
36
b36
47 (default)
b47
54
b54
65
b65
72
b72
90*
b90
* The 90 m
/h setting is available in "through wall" installation only (§7).
3
5) Maximum speed
The maximum speed, settable from 29 to 90 m
switch.
The maximum speed can be set in the following way:
- press the MENU button until the "B" (8) letter is displayed.
- press the buttons + or - to increase or decrease the maximum speed between the values shown in the table below:
Maximum speed (8 8 )
m
/h
Display
3
29
829
47
847
54
854
65
865
72
872
90*
890
* The 90 m
/h setting is available in "through wall" installation only (§7).
3
l/s
Display
0
A00
4
A04
6
A06
8
A08
10
A10
13
A13
l/s
Display
6
b06
8
b08
10
b10
13
b13
15
b15
18
b18
20
b20
25
b25
/h (i.e. from 8 to 25 l/s), can be activated through external switch, ambient sensor or light
3
l/s
Display
8
808
13
813
15
815
18
818
20
820
25
825
/h (i.e. from 0 to 13 l/s) in the following way:
3
/h (i.e. from 6 to 25 l/s) when either of the below conditions
3
13