LEAKAGE TESTING
Never check for gas leakages with a ame or while smoking.
This appliance needs to be periodically checked for leakages and an immediate check is required if the
smell of gas is detected.
Make a soap solution using 1 part of liquid dish-washing soap to 3 parts water. The soap solution can
●
be applied with a soap bottle, brush, or rag to the leakage tested points shown in the figure beside.
The valve of the LPG cylinder should be in the "OFF" position at this point of the leakage test. Once the
●
soapy solution is applied to the gas connections, the valve of the LPG cylinder needs to be turned to
the "ON" position.
Soap bubbles will begin to form in the soapy solution if any leakage is present.
●
In the event of gas leakage, the appliance shall not be used or if alight, the gas supply shall be shut-
●
off and the appliance shall be investigated and rectified before it is used again. Tighten any leaking
fittings, then turn on gas supply and recheck.
If necessary, substitute gasket (according to EN 549 Class B2) or material used to guarantee tightness
●
(according to EN 751-1 Class I).
MAINTENANCE AND CLEANING
To enjoy years of outstanding performance from your appliance, regular services of the appliance is
mandatory as followings:
The appliance should be inspected before at least one time a year by a Qualified Service only. More
●
frequent cleaning may be required according to the use of the appliance.
Any guard or other protective device removed for servicing the appliance must be replaced before
●
operating it.
Keep exterior surfaces clean, free and clear from combustible materials.
●
Use warm soapy water for cleaning. Never use flammable or corrosive cleaning agents.
●
While washing your unit makes sure to keep the area around the burner assembly dry at all times. If
●
the gas control is exposed to water in any way, try to use it. It must be replaced.
Burner and LPG compartment circulating air passageways of the appliance must be kept clean.
●
27