Store appliance upright in an area sheltered from direct contact with inclement weather (such as rain,
sleet, hail, snow, dust and debris).
If desired, cover appliance to protect exterior surfaces and to prevent build up in air passages.
Note: Wait until appliance is cool before covering.
TROUBLESHOOTING
PROBLEM:
Burner won't light
Burner won't stay lit
Burner flame is low
Note: Do not
operate appliance
below 5˚C
Carbon build-up
Flash back (flame
inside burner)
Thick black smoke
If you can not solve trouble according to one of the mentioned solutions, please contact your dealer or
Distributor Responsible.
CONDITION:
Control knob is not in
Maximum position (big flame).
LPG cylinder valve is closed /
Empty.
Blockage in the injector.
Air in the gas circuit.
Low gas pressure.
Igniter fails.
Dirty build up around burner.
Low flames or not full running
around the burner.
Thermocouple is not operating
correctly.
Low Gas pressure.
Outdoor temperature is
greater than 5˚C and LPG
cylinder is less than 25% full.
Gas pipe is bent or kinked.
Control knob is fully Maximum
position (big flame).
Dirty or film on burner.
Burner ports are blocked.
Blockage in the burner.
SOLUTION SUGGESTED:
Turn control knob in Maximum position (big flame).
Open the valve / Replace LPG cylinder with a new one.
Clean or replace injector.
Open gas line and bleed it (pressing control knob in)
for not over 1 minute or until you smell gas.
Replace LPG cylinder with a new one.
Use match to light burner; change battery or
obtain new igniter and replace it.
Clean dirty around the burner.
Flame spreader holes partially closed; clean the burner.
Replace thermocouple (FSD).
Replace LPG cylinder with a new one.
Replace LPG cylinder with a new one.
Straighten hose and perform leakage test on gas pipe.
Turn control knob to"OFF" position (full disk), let cool to
room temperature and check burner and
orifices for blockage.
Clean burner.
Switch OFF the appliance. Close LPG cylinder valve.
Wait 2 minutes, following the ignition procedure. Ignite
burner. If problem continuous, switch-off. Contact your
dealer.
Turn control knob to "OFF" position, let the
appliance to cool at room temperature and remove
blockage and clean burner inside and outside.
29