Installation
•
According to the law, all gas equipment must be installed by competent persons in accordance with
current legislation on safety of installations and rules of use.
•
Make sure that you comply with the law.
Gas type &
Model
pressure
G30 29mbar
GAS-CR2B
GAS-IX02
G20 20mbar
G30 29mbar
GG-331
GG-332
G20 20mbar
GAS-320WB
G30 29mbar
GG-429
GASDL4
G20 20mbar
G30 29mbar
GGMCI-315
G20 20mbar
GAS419H
Gas conversion
•
Exercise caution in operations and adjustments when converting from one gas to another.
•
This work must be carried out by a qualified technician.
•
Before starting, turn off the gas and electrical power to the appliance.
1. Replace the burner nozzle
Remove the pot support, burner cap and flame spreader.
Unscrew the injector with a 7 mm spanner and replace it with the injector stipula-
ted for the new gas flow. After replacement, it is advisable to tighten the injectors in
place.
2. Adjust the minimum flame level
Turn the knob to the minimum.
Remove the knob inside the spanner shaft and tighten the small screw in the centre
of the spanner shaft. The correct setting is obtained when the flame is approximately
3-4 mm long.
Control knob
Adjustement screw
Seal ring
Heat input and orifice size marked(mm)
Wok burner
Rapid burner
3.3kW(240g/h)
3.0kW(218g/h) 1.75kW(127.5g/h)
0.91
1.39
0.97
1.41
0.93
1.28
/
/
* For butane/propane gas, the screw adjustment must be correctly
tightened.
correctly tightened.
* Replace the key in the knob.
* Make sure that the flame does not go out quickly when going from
maximum to minimum.
Make sure that the flame does not go out quickly when switching from
maximum to minimum.
Repeat this process for each of the gas connections.
34
Semi-rapidA
/
/
/
/
/
0.66
/
1.00
/
0.66
/
1.00
0.87
0.66
1.30
1.00
English
uxiliary-rapid
1.0kW(73g/h)
0.50
0.78
0.50
0.78
0.50
0.78
0.50
0.78
Injector
infiniton.es