Instalação
Before installing the hob, make sure that:
•
The work surface is square and level, and no structural furniture interferes with space requirements.
•
The work surface is made of a heat-resistant and insulating material.
•
If the hob is installed above an oven, the oven has a built-in fan.
•
The installation shall comply with all clearance requirements and current standards and regulations.
•
A suitable disconnection switch is incorporated in the fixed wiring system to allow for complete dis-
connection of the mains supply. The isolating switch shall be mounted and positioned in accordance
with local electrical installation rules and regulations.
•
The isolating switch must be approved and must provide 3 mm contact separation on all poles (or
on all active [phase] conductors if local wiring regulations allow this variation of requirements).
•
The isolating switch must be accessible to the customer after the hob has been installed.
•
Consult local building authorities and ordinances if in doubt about installation.
•
Use heat-resistant, easy-to-clean finishes (such as ceramic tile) for wall surfaces surrounding the
cooktop.
After installing the hob, make sure that:
•
The power cord is not accessible through cabinet doors or drawers.
•
There is an adequate flow of fresh air from the outside of the cabinet to the base of the hob.
•
If the hob is installed on top of a drawer or cabinet, a thermal protection barrier must be installed
under the base of the hob.
•
The isolation switch is accessible to the customer.
51
Portuguese
infiniton.es