Descargar Imprimir esta página

Hitachi ATW-YCC-03 Manual De Instalación Y Funcionamiento página 15

Ocultar thumbs Ver también para ATW-YCC-03:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 33
LCD REMOTE CONTROLLER
8.3 CASCADE CONTROLLER CONFIGURATION
Select the desired language using the arrow keys.
Press OK button.
Select the date and time using the arrow keys.
Select Enabled or Deactivated for European summer time.
Press OK button.
Select the controller type:
-
Unit: the device controls the unit.
-
Room: the device acts as a room thermostat of a zone.
-
Unit + Room: the device controls the unit and acts as a
room thermostat.
Select the display theme:
Light: normal view.
-
-
Dark: black background with white icons.
-
Auto: changes automatically to light at 08:00 am and
turns to dark at 20:00 pm.
9
PMML0581 rev.1 - 02/2023 - 1000011627
Configure circuit 1 and circuit 2 OTC: Deactivated, Points,
Gradient, Fix.
Enable or disable DHW and Swimming Pool.
Select the heating source: HP only, HP + EH, HP + Boiler.
Configure electrical heater use: Starting or Backup.
Configure Boiler type: Parallel or Serial.
Configure Solar Combination options: Deactivated, Input
Demand, Total Control. (only in case DHW is enabled).
Select Next and press OK button.
Configure circuit 1 and circuit 2 options (Only available for
cooling mode): Deactivated, Points, Gradient, Fix.
Select Next and press OK button.

Publicidad

loading