Specifications
Head Type
Square drive Fixed and Flex Quick Release 36 teeth Ratchet.
Display
DISPLAY TYPE: Dot Matrix LCD (168 x 48 Resolution) and (192 x 65 Resolution)
VIEWING ANGLE: 6:00
BACKLIGHT: WHITE (LED)
Sealed Button Pad
POWER - ON/OFF and torque and angle re-zero
ENTER - measurement mode select and menu entry
UP – increments torque and angle settings and menu navigation
DOWN - decrements torque and angle settings and menu navigation
UNITS - units select (ft-lbs, in-lbs, in-oz (depending on range), Nm, Kg-cm, dNm or cNm
depending on range) and enter PSET (preset) menu
LCD BACKLIGHT – Illuminates all screens and last peak torque or angle recall
Functions
Set - torque or angle target
Track - real time display of torque or accumulated angular rotation with progress lights
Peak Hold – 5 sec. flashing of peak torque or alternating peak torque/angle on release of torque
Peak Recall - display last peak torque or peak torque/angle on button press
Memory - display of last 50 peak torque or peak torque/angle readings
Accuracy
Temperature: @ 22 C (72°F)
Angle: ±1% of reading ±1° @ angular velocity > 10°/sec < 180°/sec
CW
Torque:
±2% ±3% of reading, 20% to 100% of full scale
(Unflexed)
±4% ±6% of reading, 10% to 19% of full scale
±8% ±10% of reading, 5% to 9% of full scale
Operating Temperature: 0°F - 130°F (-18°C to 54°C)
Storage Temperature:
Measurement Drift:
Humidity:
Battery:
Default Auto Shut-off:
CCW
0°F to 130°F (-18°C to 54°C)
ANGLE: -0.12 Angular Degrees per Degree C
TORQUE: +0.01% of reading per Degree C
Up to 90% non-condensing
Micro Series: Single "AA" alkaline Cell, up to 40 hours continuous operation.
Alkaline or rechargeable NiMH batteries may be used (exceeds ASME
battery life requirement of 10 hours continuous operation).
Standard Series: Three "AA" Alkaline Cells, up to 80 hours continuous
operation
After 2 minutes idle – (Adjustable, see Advanced Settings)
3