SETTING THE ELECTROLYSIS SYSTEM TO MANUAL MODE
Set- the- electrolysis- system- to- standby- mode-
(see- the- section- entitled- "SETTING- THE-
ELECTROLYSIS-
SYSTEM-
MODE).
Press-the-"MAN"-key-on-the-control-panel-of-the-
electrolysis- system- with- integrated- pH- /- ORP-
control.
The-display-will-show-a-number-between-brackets,-
"<XX>"- indicating- the- percentage- amount- of-
chlorine-produced-by-the-system.
Use-the-"-"-and/or-""-keys-to-set-the-chlorine-
production-percentage-for-the-system-(from-10%-
to-100%).
Each time the system is started up again, it
will automatically operate in manual mode.
In this mode, the system will continue to
operate, producing active chlorine in a
continuous and notable manner until it is set
to Standby mode by the operator.
Keep manual operation mode use to a minimum, limiting it to those times when it is necessary
to increase the water chlorination independently of the control parameters. This must be done
when the product is not in use.
WATER-TREATMENT-KIT
TO-
STANDBY-
pH
Electrolysis
ORP mV
7.0 ... 7.8 pH
Setpoint
Control Mode
Setpoint
AUTO
SET
MAN
CAL
STOP
pH CONTROLLER
ORP CONTROLLER
ON
ALARM
Electrolysis
pH
7.0
-----
7.2
STOP
Control Mode
Setpoint
pH
Electrolysis
ORP mV
7.0 ... 7.8 pH
Setpoint
Control Mode
Setpoint
AUTO
SET
MAN
CAL
STOP
pH CONTROLLER
ORP CONTROLLER
ON
ALARM
EN
650...800 mV
SET
CAL
ORP mV
690
700
Setpoint
650...800 mV
SET
CAL
19