SYSTEM ALARMS AND MESSAGES
ALARM
pH
Electrolysis
LOW
ORP
7.2
« AUTO »
Setpoint
Control Mode
pH
Electrolysis
HI
ORP
7.2
« AUTO »
Setpoint
Control Mode
pH
Electrolysis
FLOW
ALARM
Setpoint
Control Mode
pH
Electrolysis
HI
ORP
7.2
MAN
Control Mode
Setpoint
pH
Electrolysis
7.0
ORP
7.2
HI SALT
Setpoint
Control Mode
Electrolysis
pH
7.0
ORP
7.8
LOW SALT
Control Mode
Setpoint
In- all- of- the- cases- described- here- above,- the- alarm- LEDs- on- the-
control-panel-will-begin-to-blink.
24
PROBLEM
The- integrated- pH- controller- has- two-
alarm- states- (HI/LOW),- which- are-
ORP mV
reached- when- a- value- outside- of- the-
LOW
range 6.5 – 8.5-pH-is-found.-When-the-
system-identifies-an-enabled-alarm,-the-
700
metre-pump-is-disenabled.
Setpoint
AUTOMATIC MODE:
On-the-other-hand,-the-integrated-ORP-
controller- has- one- alarm- state- only,-
ORP mV
which- is- triggered- when- the- values-
exceed- > 850 mV.- The- system- stops-
HI
the- electrolysis- process- when- this- limit-
700
is-passed.
Setpoint
There- is- no- water- flow,- or- the- flow- is-
insufficient.
ORP mV
IMPORTANT:- the- in-out- valves- of- the-
electrolyte- cell- must- always- remain-
open.
Setpoint
MANUAL-MODE:
The-system-deactivates-the-CONTROL-
ORP mV
of-the-production-of-chlorine-in-manual-
HI
mode.- Production- only- ceases- when-
the-ORP-reaches-999-mV.
700
Setpoint
Excess- salt- has- been- added- to- the-
water.
ORP mV
690
700
Setpoint
There-is-insufficient-salt-in-the-water.
ORP mV
690
700
Setpoint
SOLUTION
In-this-case,-the-chemical-values-for-the-
water-need-to-be-adjusted-manually-by-
adding-chemicals.-
If-there-is-excess-chlorine-in-the-water,-
cease-all-bathing-activities-and-replace-
some-or-all-of-the-water.
Make- sure- that- the- valves- are- open-
and/or- that- the- flow- of- water- is-
sufficient.
Make- sure- that- no- lead- has- been-
detached- from- the- cell- or- inside- the-
control-box).
Deaerate- the- electrolyte- cell,- using- the-
air-vents-on-same.
This is not an anomaly, the- alarm-
signal- will- cease- when- the- system- is-
returned-to-"AUTO"-mode.
If-there-is-excess-chlorine-in-the-water,-
cease-all-bathing-activities-and-replace-
some-or-all-of-the-water.
Remove-some-water-and-top-up-again.
Add- 500- g- salt- and- wait- for- half- an-
hour;- if- the- message- does- nota-
disappear,-repeat-the-operation.
ALARM
WATER-TREATMENT-KIT