» Features for Factory
This menu allows modifying the operation
parameters of the thermostat, electronic motor,
version +/- 3 and many other parameters.
With the control set on "OFF", press the M and
Fan buttons simultaneously for 3 seconds.
Select the parameter to be modified pressing
the "+" or "-" buttons and confirm using the "M"
button.
F
UNCTION
OFS
dEds
dEdr
IrL
F
F
UNCTION
UNCTION
dS
dS
F
F
UNCTION
UNCTION
T2-1
T2-1
T2-2
T2-2
F
UNCTION
T3-1
T3-2
I-T3
F
F
UNCTION
UNCTION
t1ds
t1ds
F-t1
F-t1
F-t2
F-t2
F-t3
F-t3
F
UNCTION
Slu1
SCu2
SHu3
LLSI
HLSI
LLSE
HLSE
PFC
PFH
F
F
UNCTION
UNCTION
Pt1
Pt1
Pt2
Pt2
Pt3
Pt3
F
UNCTION
rE-t
THERMOSTAT PARAMETERS
D
ESCRIPTION
Thermostat NTC probe offset variation
Dead area central point
Dead area setting field
Relay hysteresis
y y
THERMOSTAT PARAMETERS
THERMOSTAT PARAMETERS
D
D
ESCRIPTION
ESCRIPTION
Variation range of set with T–MB
Variation range of set with T–MB
PARAMETERS of the T2 probe, CHANGE-OVER
PARAMETERS of the T2 probe, CHANGE-OVER
D
D
ESCRIPTION
ESCRIPTION
Status changeover from ventilation to cooling
Status changeover from ventilation to heating
Status changeover from ventilation to heating
PARAMETERS of the T3 probe, TME minimum probe
D
ESCRIPTION
Fan ON in heating mode
Fan ON in cooling
T3 probe hysteresis
PARAMETERS of the Stratification Cycle
D
D
ESCRIPTION
ESCRIPTION
Unbalancing of air probe T1 for winter cycle (only for Cassettes)
Unbalancing of air probe T1 for winter cycle (only for Cassettes)
Fan OFF time
Fan OFF time
RL2 ON time
RL2 ON time
Post-ventilation time
Post-ventilation time
THERMOSTAT PARAMETERS
D
ESCRIPTION
Speed min. voltage
Speed medium voltage
Speed max. voltage
Speed min. voltage for winter auto fan
Speed max. voltage for winter auto fan
Speed min. voltage for summer auto fan
Speed max. voltage for summer auto fan
Cooling proportional fan
Heating proportional band
g p p
PARAMETERS of the Pump Timer
PARAMETERS of the Pump Timer
D
D
ESCRIPTION
ESCRIPTION
Pump intervention delay time
Pump intervention delay time
OFF Time in Summer
OFF Time in Summer
ON Time in Summer
ON Time in Summer
OTHER FUNCTIONS
D
ESCRIPTION
General reset and restore of Default values
Once the parameter is selected, the value will
be displayed.
The value can be modified using the "+" or "-"
buttons.
Press the "M" button once to turn back to the
parameter selection;
to exit the menu, press the "M" button for more
than 5 seconds.
35
English
R
D
ANGE
EFAULT
± 3°C
0°C
18 ÷ 30°C
22°C
1 ÷ 6°C
2°C
0.5 ÷ 2.0°C
0.7°C
R
R
D
D
ANGE
ANGE
EFAULT
EFAULT
± 9°C
± 9°C
± 3°C
± 3°C
R
R
D
D
ANGE
ANGE
EFAULT
EFAULT
15 ÷ 25°C
15 ÷ 25°C
< 22°C
< 22°C
25 ÷ 35°C
25 ÷ 35°C
> 32°C
> 32°C
R
D
ANGE
EFAULT
> 30 ÷ 40°C
> 36°C
< 10 ÷ 25°C
< 22°C
2 ÷ 6°C
4°C
R
R
D
D
ANGE
ANGE
EFAULT
EFAULT
0.5 ÷ 2.0°C
0.5 ÷ 2.0°C
1.5°C
1.5°C
5÷ 13 min
5÷ 13 min
10 min
10 min
30 ÷ 120 sec
30 ÷ 120 sec
40 sec.
40 sec.
5 ÷ 240 sec
5 ÷ 240 sec
60 sec.
60 sec.
R
D
ANGE
EFAULT
1 ÷ 6
1 V
3 ÷ 8
5 V
6 ÷ 10
10 V
1 ÷ 6
1 V
5 ÷ 10
10 V
1 ÷ 6
1 V
5 ÷ 10
10 V
2.0 ÷ 6.0
3.5°C
2.0 ÷ 6.0
3.5°C
R
R
D
D
ANGE
ANGE
EFAULT
EFAULT
0 ÷ 300 sec
0 ÷ 300 sec
150 sec.
150 sec.
30÷ 90 min
30÷ 90 min
60 min
60 min
0÷ 5 min
0÷ 5 min
3 min
3 min
O
PERATION
Confirmation with O/I and Fan buttons