SW 4: Signaling AM or TF output
On: Signals AM on both the AM and Alarm relays. Signals TF
on the AM relay only (EN 50131).
Off: Signals AM and TF on the AM relay (factory default).
SW 5: Setting LEDs
On: Enables both LEDs on the detector at all times (factory
default).
Off: Puts both LEDs under the control of the Walk Test and
Day/Night input. This activates the memory feature of the
detector.
AM calibration
During start-up the AM circuitry calibrates itself to its
environment. It is important to make sure that there are no
changes made to the environment within 1 m distance of the
detector within 60 s after powering up, otherwise the detector
may be vulnerable to false AM alarms and these alarms may
be impossible to reset.
LED indication
PIR
Red LED
Alarm relay
Start up
Closed
Low voltage
Open (Alarm)
PIR intruder
Open (Alarm)
alarm
Red
Yellow
PIR/AM
LED
LED
Start up
Low voltage
PIR intruder
alarm
Latched PIR
(Memory)
AM alarm
After AM
reset
Technical
fault
Continuously on
Normal blinking (1 Hz)
Fast blinking (4 Hz)
* Depends on the setting of the DIP switch SW4.
Specifications
Detector
Signal processing
Range
Optical
Memory
Input power
P/N 146279999-2 (ML) • REV Q • ISS 10JUN21
To reset
Automatically after 25 s
Apply correct voltage
Automatically after 3 s
Alarm
AM
To reset
relay
relay
Closed
Closed
Automatically
after 60 s
Open
Open
Apply correct
(Alarm)
(Alarm)
voltage
Open
Automatically
(Alarm)
after 3 s
Switch to Night
mode
Open*
Open
See DIP
(Alarm)
(Alarm)
switch 3
Switch to Night
mode
Open
Do a successful
(Alarm)
walk test
PIR
PIR with anti-
masking
V2E
20m
11 high-density mirror curtains
Yes
9 to 15 VDC (12 V nominal)
Detector
Peak-to-peak ripple
Detector start-up time
Normal current
Current in alarm
Maximum current
(LED on)
Mounting height
Target speed range
Alarm (NC) / Tamper relay
characteristic
Pry-off tamper
AM relay characteristic
PIR Alarm time
Operating temperature
Dimensions (H x W x D)
Relative humidity
Weight
IP/IK rating
Regulatory information
Manufacturer
PLACED ON THE MARKET BY:
Carrier Fire & Security Americas Corporation Inc.
13995 Pasteur Blvd
Palm Beach Gardens, FL 33418, USA
AUTHORIZED EU REPRESENTATIVE:
Carrier Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Product warnings
THESE PRODUCTS ARE INTENDED FOR
and disclaimers
SALE TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. CARRIER FIRE &
SECURITY CANNOT PROVIDE ANY
ASSURANCE THAT ANY PERSON OR ENTITY
BUYING ITS PRODUCTS, INCLUDING ANY
"AUTHORIZED DEALER" OR "AUTHORIZED
RESELLER", IS PROPERLY TRAINED OR
EXPERIENCED TO CORRECTLY INSTALL
FIRE AND SECURITY RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/ or scan the QR code.
Certification
FCC
Note:
This equipment has been tested and found
to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference in
a residential installation. This equipment
generates, uses and can radiate radio frequency
energy and, if not installed and used in
accordance with the instructions, may cause
harmful interference to radio communications.
However, there is no guarantee that interference
will not occur in a particular installation. If this
equipment does cause harmful interference to
PIR
PIR with anti-
masking
2 V (at 12 VDC)
25 s
60 s
6.5 mA
10 mA
1.2 mA
3.8 mA
11 mA
24 mA
1.8 to 3.0 m
2.0 to 3.0 m
(5.9 ft.to 9.8 ft.)
(6.6 ft.to 9.8 ft.)
30 cm/s to 3 m/s
20 cm/s to 3 m/s
(1 ft./s to 10 ft./s)
(0.65 ft./s to 10 ft./s)
80 mA, 30 VDC,
80 mA, 30 VDC
resistive
Optional
Onboard (yes)
—
80 mA
at 30 VDC max.
3 s
−10 to +55°C (+14 to 130°F)
125 × 55 ×
125 × 65 × 60 mm
60 mm (4.92 x
(4.92 x
2.16 x 2.36 in.)
2.6 x 2.36 in.)
95% max. noncondensing
150 g
IP30 IK02
5 / 38