Descargar Imprimir esta página

VITO VIGI3000 Manual De Instrucciones página 47

Publicidad

Idiomas disponibles

Idiomas disponibles

At high altitude, the usual air–fuel mixture will be extremely
rich. Performance will decrease and fuel consumption will
increase. A very rich mixture will decrease the spark and
cause a bad start.
High altitude performance can be improved by installing
thinner fuel hoses in the carburettor and adjusting the idle
speed. If you always use the generator at altitudes above 15
00m above sea level, you should seek specialised technical
assistance to make the necessary adjustments. Even with
proper fuel injection, generator power decreases by an
average of 3.5% for every 300m increase in altitude. The
effect of altitude on power will be greater if the necessary
adjustments are not made.
If an engine prepared for high altitudes is used at low
altitudes,
the
performance levels and may overheat the engine causing
serious engine damage.
Parallel operation enables the power combination (Table 1)
of 2 inverter generators, regardless of the model.
This connection is possible with the use of parallel
connection cables, which allow a higher output power
compared to individual use.
All models of VITO inverter generators are designed to
operate either alone or in parallel.
Table 1 - Parallel connections and resulting characteristics.
Rated
Pairing
power
generators
Two VIGI4000
7600
watts
Two VIGI3000
6400
watts
Two VIGI2000
3600
watts
Two VIGI1250
2000
watts
VIGI4000 and
7000
VIGI3000
watts
VIGI4000 and
5600
VIGI2000
watts
VIGI3000 and
5000
VIGI2000
watts
VIGI4000 and
4800
VIGI1250
watts
VIGI3000 and
4200
VIGI1250
watts
VIGI2000 and
2800
VIGI1250
watts
air-fuel
mixture
will
Maximum
Autonomy
power
(100%)
5 h
8000
watts
5 h
7000
watts
4000
3,5 h
watts
2500
3,5 h
watts
7500
5 h
watts
5 h
6000
watts
5500
5 h
watts
5250
5 h
watts
4750
5 h
watts
3250
3,5 h
watts
Generator
VIGI4000
VIGI3000
VIGI2000
VIGI1250
Assembly:
reduce
Before any maintenance or cleaning work, place the
appliance on an even surface, and remove the cap
from the spark plug.
Do not run the engine with low oil level as this can
cause serious engine damage.
1. Place the generator on a firm and steady floor;
2. Remove the oil level inspection cover (5A) and oil filler
cap;
3. Using the funnel, fill the specified quantity of
Autonomy
recommended oil (15W40) and fit the filler cap;
(50%)
4. Remove the oil level inspection cover (5A);
8,5 h
To change the oil:
8,5 h
Avoid draining the engine oil immediately after stopping the
6 h
engine.
5,2h
5. Place the generator on a level floor surface, and warm up
the engine for a few minutes. Then turn 3 in 1 switch to
8,5 h
"OFF";
8,5 h
6. Remove the oil level inspection cover;
7. Remove the oil filler cap;
8,5 h
8. Place an oil tray under the generator. Tilt the generator
8,5 h
so as to remove the oil from the tank;
9. Make sure you have the generator on a level surface when
8,5 h
you put the new oil in;
10. Add oil up to the level;
6 h
11. Clean the cap and any oil that may have spilled;
12. Replace the tank cap;
13. Fit the cover and tighten the bolts.
Table 2- Individual use characteristics.
Rated
Maximum
Autonomy
power
power
3800
4000
watts
watts
3200
3500
watts
watts
1800
2000
watts
watts
1000
1250
watts
watts
Autonomy
(100%)
(50%)
5 h
8,5 h
5 h
8,5 h
3,5 h
6 h
3,5 h
5,2h

Publicidad

loading