Display
Reason
F6, F7,
Motor current has
F8
reached the set stop
overcurrent level
F9
Maximum admissible
energy has been
accepted by the motors
(heat factor)
Hot
Maximum admissible
(F10)
energy has been emitted
by the control unit
(heat factor)
Hot
Max. temperature for
(F11)
switching power supply
unit reached
Hot
Max. temperature of the
(F12)
output stages for 1st or
2nd motor reached
Hot
Max. temperature of the
(F13)
output stages for 3rd or
4th motor reached
F14
Max. position deviation
exceeded
F15
Motor blocked /
overloaded
F16
Number of lifting
modules does not
correspond to the
confi guration
F17
Control unit overloaded
The solution
Reduce the load or provide for easier movement
of the frame
Push a button to reset the error.
Wait until the motors have cooled down. The heat
factor is automatically counted back so that already
after about one minute, the motors can be operated
again. It takes about 10 minutes until the heat factor
has returned to 0.
Push a button to reset the error.
Wait until the control unit has cooled down.
The heat factor is automatically counted
back so that already after about one minute,
the control unit can be operated again. It
takes about 10 minutes until the heat factor
has returned to 0. Push a button to reset the
error.
Wait until the output stages of the control unit have
cooled down.
Push a button to reset the error.
The control unit automatically switches into the
reference mode.
Referencing (see section 9.35 "Referencing")
Reduce the load of the table or provide for easier
movement of the table frame.
Push a button to reset the error.
Check whether all lifting modules have been correctly
connected to the control unit. Push a button to
reset the error. Less control units, see section 15
"Resetting the number of connected lifting modules".
See F1-F4
3 842 564 712/2022-06, MPS: Steuergerät, Bosch Rexroth AG
Troubleshooting
27/36