34/36
Technical data
17.1 Ambient conditions
• The control and the accessories are intended for the stationary use in light
industrial indoor areas. With higher requirement, the components have to be
attached and installed with corresponding protection.
• Operating temperature: +5 °C to +45 °C
• Storage temperature –20 °C to +60 °C
• Relative humidity: max. 95%, non-condensing
• Installation height: max. 2,000 m a.s.l.
• Upstream supply fuse: EU ≤ 16 A, USA/CAN ≤ 15 A
• The area should be kept free of mold, fungus, rodents and other vermin.
• Do not install or operate in the immediate vicinity of industrial equipment
producing chemical emissions.
• Do not install or operate near sources of sand or dust.
• Do not install or operate in areas that are regularly subjected to high-energy
forces caused, for example, by presses or heavy machinery.
17.2 Lifting tables according to DIN EN 1570
• For the required IP54, measures on the user side are necessary
(control unit: IP40)
• The lifting modules and controls are optimized for pulling power.
150% limitation of the motor torque according to DIN EN 1570 has to be
provided by the user.
Bosch Rexroth AG, MPS: Steuergerät, 3 842 564 712/2022-06