32/36
Resetting the pressure wave sensor to automatic detection
Button / display
or
P17
Button [1]
or
P91
Button [1]
16 Resetting the pressure wave sensor to automatic
detection
The control unit automatically detects the pressure wave sensor.
If the connection adapter is unplugged or gets loose, the control will stop and
output error message F21.
If the control unit is to be operated without pressure wave sensor, the automatic
detection must be activated.
Button / display
or
P14
Button [1]
P60
or
P61
Button [1]
Bosch Rexroth AG, MPS: Steuergerät, 3 842 564 712/2022-06
Instructions
Push shortly four times in a row
A tone sequence resounds and "PXX" is shown in the display
(A)
Push to select a menu item
Distribution menu
Push to select menu item
The display shows "P90"
Push to select a menu item
Reset the Basic distribution
Push to restart the stroke.
The stroke now continues the operation.
Instructions
Push shortly four times in a row
A tone sequence resounds and "PXX" is shown in the display
(A)
Push to select a menu item
Reset menu
Push to select menu item
No. of lifting modules
Push to select a menu item
Select menu item
Push to select menu item
1: Safety adapter active, (only with adapter)
2: Automatic detection active, (without adapter)