3.4 I Adjusting the water flow
• The filtration pump must be operating.
• Check the water flow regularly to ensure the best possible cleaning performance and to make it easier for the cleaner
to climb the sides.
• The cleaner is equipped with a flow regulator valve which automatically adjusts the water flow through the cleaner. It
indicates whether the water flow is ok or excessive: YELLOW = flow ok / RED = flow excessive
3.4.1 Checking the wheel rotation speed
• The filtration pump must be operating.
• Switch on the filtration pump (have a stopwatch ready).
• Raise the cleaner to below the surface of the water, keeping it submerged.
• Note the yellow indicator on the rear right wheel (see image
• For MX8 - MX8 PRO - MX9: Wait until the wheels change direction and log the time until the wheels have performed
10 turns (see image
• Adjust the water flow according to the time logged (see image
3.4.2 Adjusting the water flow
• Adjust the water flow using the flowkeeper valve provided with the device (see image
9
).
10 turns
: Flow regulator valve
: Control
).
).
Seconds
26-50
20-25
10-19
(+) Increase the flow
(-) Reduce the flow
Increase the flow
Flow ok
Reduce the flow
), or from the pool valves.