water to the device. The main valve should be installed in an easily accessible place; for this reason, it should
not be installed behind the device. The cycle duration was given for the feed water temperature of 50°C. In
the event the device is connected to cold water, the cycle duration time may increase, because the device is
equipped with a constant temperature pressure rinse system.
4.4. Drain hole
The device is equipped with a drain pipe which should be installed at floor level with the use of siphon
Before starting the device, make sure that the supply pipe and the drain pipe were not bent, jammed
or otherwise damaged during installation.
4.5. The first start-up
Before starting the machine, check the correct operation of the electrical protection system. The abo-
ve steps and the first start-up of the device may only be performed by the employees of the technical servi-
ce, who will also conduct a brief training concerning the functioning of the device. Each device is equipped
with an adjustable rinse aid dispenser. Meanwhile, only select models of the device are equipped with a
detergent dispenser with the possibility of adjustment. The detergent and rinse aid containers should be
placed in the proper location and then the suction tubes should be connected: the clear tube to the de-
tergent and the blue tube to the rinse aid. For adjustment, use the adjustment screws shown in fig. 4. It is
recommended for the adjustment to be performed by the personnel of the company supplying the rinse aid
and detergent. Before connecting the suction tubes it is necessary to attach weights (in order to keep the
tubes on the bottom of the containers) and put on the filters ( fig. 5).
In the event the dispensers have not been installed before the installation of the device, it can be done at a
later time using an appropriate set of tools. Alternatively, an external detergent dispenser may be connected
through an electric connection using a 2x0,5mm2 H07 RN-F electric cable. The cable should be connected
through the passage indicated on the technical data diagram, in accordance with the electrical parameters
of the device and the applicable legal provisions. Dispenser parameters: 230V/50Hz, 8W. The detergent
dispenser should be connected to the dishwasher using a clear tube.
5. HEALTH & SAFETY RULES
In order to prevent burns and electric shock please observe the following safety rules:
• training of staff in the use of the device in accordance with the information contained in this instruction
manual
• training of the personnel in the scope of the basic principles of operation of electrical appliances, wor-
kplace safety and provision of first aid in case of need,
• before starting any maintenance work, disconnect the device from the power supply,
• it is prohibited to turn the device on, if any heating element and/or control element is damaged.
The manufacturer is not liable for any injuries or damage to the product resulting from failure to comply
with the recommendations contained in the instruction manual, improper use of the device, use of non-ori-
ginal spare parts and attempts to repair the device independently.
• The device should be connected to an electrical grid with grounding in accordance with the applicable
regulations and standards.
• The device complies with the standards introduced under the European Union's Directives. The proper
storage of the device is an element of prevention of the pollution of the environment.
Do not add solvents such as alcohol or turpentine to the dishwasher as they can cause an explosion.
It is also prohibited to place dishes with remnants of food products in the dishwasher.