ELECTRIC SPECIFICATIONS
DC VOLTAGE
Range
Resolution
200 mV
0,1 mV
20 V
10 mV
200 V
100 mV
1 000 V
1 V
Input resistance: 5 M in mV range
Other ranges: 5 M
Overload protection: 250 V DC or maximum value of AC
in 200 mV range
Maximum value: 1 000 V DC or AC in other ranges.
AC VOLTAGE REAL RMC
Range
Resolution
200 V
100 mV
750 V
1 V
Input resistance: 10 M
Overload protection: 1 000 V DC or AC peak value
Frequency maximum value response: (40 – 1 000) Hz
(For standard sine wave and triangular wave)
Display: Real RMS (only as reference, when over 200 Hz in other waves).
In AC range 750 V; AC 380 V can be tested and, 220 V commercial
energy. Press the key "HOLD" to show commercial energy frequency.
DC CURRENT
Range
Resolution
200 mA
100 µA
20 A
10 mA
Overload protection: 250 V DC peak value
When using automatic recuperation fuses after eliminating the external
fault, the fuse goes back to normal and the multimeter can be used in a
normal manner.
Precision
(0,8% de rdg + 5 dgts)
(0,8% de rdg + 3 dgts)
(1% de rdg + 5 dgts)
Precision
(1,0% de rdg + 8 dgts)
(1,2% de rdg + 8 dgts)
Precision
(1,2% de rdg + 8 dgts)
(1,2% de rdg + 8 dgts)