2.12
Setting the heat curve
B
4
90
80
70
60
50
40
30
20
15
10
5
A
Outside temperature °C
The figure shows the possible heat curves of 0.1 to 4.0 for a
target room temperature of 20 °C. If, for example, heat curve
0.4 is selected, a flow temperature of 40 °C is maintained at
an outdoor temperature of -15 °C.
B
70
60
50
40
30
22
15
10
5
20
C
D
18
A
Outdoor temperature °C
B
Target flow temperature
°C
If the heat curve 0.4 is selected and 21 °C is specified for the
target room temperature, the heat curve is then translated,
as shown in the figure. The heat curve is displaced accord-
ing to the value of the target room temperature along axis a
which is angled at 45°. At an outdoor temperature of -15 °C,
the control system provides a flow temperature of 45 °C.
2.13
Display, control elements and symbols
62
3.5
3
2.5
2
1.8
0
-5
-10
-15
-20
B
Target flow temperature
°C
0
-5
-10
-15
-20
C
Target room temperat-
ure °C
D
Axis a
2.13.1 Control elements
Calling up the menu
Back to the main menu
Confirming a selection/change
1.5
Saving set values
1.2
One level back
1.0
Cancelling input
0.8
Navigating through the menu structure
0.6
Reducing or increasing the set value
Navigating to individual numbers/letters
0.4
0.2
0.1
A
Calling up help
Calling up the time programme assistant
Active control elements light up green.
Press
once: You access the basic display.
Press
twice: You access the menu.
2.13.2 Symbols
Time-controlled heating active
Button lock active
0.4
Maintenance required
Fault in the heating installation
A
Contact the competent person
Noise reduction mode active
Most energy-efficient heating mode active
Operating and installation instructions 0020287900_03