PARKSIDE PDM 300 C3
Direct Current
Range
200 μA
2000 μA
20 mA
200 mA
2 A
10 A
Overload protection:
Maximum input current: 10 A (input current > 2 A for continuous measurement <
10 seconds and interval > 15 min.)
Alternating current
Range
200 μA
2000 μA
20 mA
200 mA
2 A
10 A
Overload protection:
Maximum input current: 10 A (input current > 2 A for continuous measurement <
10 seconds and interval > 15 min.)
Frequency range: 40 Hz to 400 Hz
Display: Root mean square value (RMS of sine wave)
28 - English
Resolution
0.1 μA
1 μA
0.01 mA
0.1 mA
0.001 A
0.01 A
F1: F 250 mA / 300 V fuse
F2: F 10 A / 300 V fuse
Resolution
0.1 μA
1 μA
0.01 mA
0.1 mA
0.001 A
0.01 A
F1: F 250 mA / 300 V fuse
F2: F 10 A / 300 V fuse
Precision
± (1.0 % + 5)
± (1.2 % + 5)
± (2.0 % + 5)
Precision
± (1.2 % + 5)
± (1.5 % + 5)
± (3.0 % + 7)