Service
More frequent overhaul may be needed if the machine is used in heavy-duty op-
erations.
If the machine is not working properly, it should immediately be taken away for
inspection.
Repair
Controller
Required tools:
• Screwdriver T8
• Small flat-bladed screwdriver
Opening the cover
1. Remove the four screws indicated by circles.
Do not open the unit when faced down.
2. With the unit in upright position, open the housing carefully to the left.
Do not strain the flat cable from the front.
Do not loose the USB isolator.
Changing the front panel
1. Open the connector using a small screwdriver and carefully pull out the flat
cable.
2. Unscrew the tool holder.
3.
• Peel off the front panel. You can press from the inside on the display
window.
• Clean the inside surface of the cover with spirit.
Do not loose the light pipe.
4. Peel off the protection covers from the self-adhesive panel.
• One cover protecting the self-adhesive sections.
• One cover protecting the inside of the transparent window.
• One cover protecting the outside of the transparent window.