Descargar Imprimir esta página

Atlas Copco MT Focus 400 CHN Instrucciones Del Producto página 8

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 72
Installation
Pin
1
2
3
Vacuum pump output (VP)
5-pole socket connector for the connection of Atlas Copco Vacuum pump
VPX6 (24 V, 600 mA).
Use a 5-pole pin plug from the Binder 719 Series.
Pin
1
2
3
4
5
Configurable single input (I/O)
5-pole pin connector, configurable, e.g. as input for foot switch.
For information on configuration of the input, see ToolsTalk MT - Reference -
I/O status.
Use a 5-pole socket plug from the Binder 719 Series.
NOTICE
• This input is not opto-isolated.
Input resistance
NOTICE
• If used to reset the tool, the signal duration must be more than 40 ms.
Pin
1
2
3
4
5
8
Signal
TxD
GND
RxD
Output
+24 V
+24 V
Pump on
GND (0 V)
GND (0 V)
Output
+24 V
GND (0 V)
Digital in
© Atlas Copco Industrial Technique AB - 9836 791600 00
EN
Description
Transmitted data
Data ground
Received data
Description
Internal +24 V
Internal +24 V
Digital output
Internal 0 V
Internal 0 V
10 kΩ
Description
Internal +24 V
0 V output
Digital input
MT Focus 400
Default
Default
Start tightening

Publicidad

loading

Este manual también es adecuado para:

8432 0850 03