Closed expansion tank system with heat exchanger and optional thermostat valve
1.3
USE AND MAINTENANCE
1.3.1
PRELIMINARY
CHECKS
Before the use of the boiler, it is neces-
sary to follow the following instructions:
– The installation where the boiler is
connected to, should be preferably
with an open expansion tank (fig. 9).
– The tube, which connects the boiler
to the expansion tank, should have an
adequate diameter according to the
norms in force.
– The heating pump should always be
running during the operation of the
boiler.
– A possible ambient thermostat should
never interrupt the pump operation.
– If the installation is equipped with a
3 or 4 ways mixing valve, it should
always be placed in the opening posi-
tion toward the installation.
– Be assure that the draught regulator
works regularly and that there aren't
impediments, which block the auto-
matic operation of the air gate damp-
er.
CLEANING
The cleaning should be carried out with
16
a certain frequency providing besides
the cleaning of the smoke passages,
also the cleaning of the ash box, remov-
ing the ashes, which are contained in
IGNITION
the collection basin. Use a proper pull-
through for the cleaning of the smoke
passages (fig. 11).
1.3.2
MAINTENANCE
Do not perform any maintenance work,
dismantling or removal of parts without
properly emptying the boiler first.
The boiler must not be emptied when
the water is hot.
CAUTION:
The safety valve on the system must
be inspected by technically quali-
fied personnel in accordance with the
laws of the country of distribution and
instructions for use of the safety valve.
If the system is completely emptied
and remains unused for some time, the
safety valve must be inspected before it
is used again.If the safety valve should
malfunction and cannot be re-calibrat-
ed, replace it with a new 1/2" valve cali-
brated to 3 BAR and conforming with
Directive PED 2014/68/UE.
LE GEN D
VE Expansion tank
VS System safety valve 3 BAR - 1/2"
VM Mixing valve
VR Check valve
PI System pump
IR Heating system
VT Thermostat valve
SC Safety exchanger
F Filter
CAUTION: The safety exchanger is supplied in an
8105200
optional kit code
.
Temperature of the water supplied to the safety
heat exchanger: 10°C.
Pressure of the water supplied to the safety heat
exchanger: 2 bar.
Fig. 10
Fig. 11