Control panel with display:
1 - Display
2 - Control buttons
3 - RS232 socket
4 - ON/OFF switch
3.2.
Installation of the unit
The mounting plate of the scale should be attached to the wall with the use of appropriate mounting
pins/anchors, depending on the material of the wall to which the scale will be attached. Remember that the
wall (with mounting pins/anchors) needs to withstand the maximum weight load depending on the model
(150 kg for the SBS-PWS-150 model or 300 kg for the SBS-PWS-300 model).
Attach the scale using all mounting holes on the mounting plate.
3.3.
Working with the machine
After mounting the scale on the wall, you can start working.
Turn on the scale by pressing the ON/OFF button.
ZERO - Reset function. It should only be used when there is nothing on the scale and the display does not
show "0". The scale may not read "0" due to dust, dirt, or moisture on the weighing pan or when a heavy
object is dropped on the scale. The zeroing function essentially corrects the true zero on the scale and informs
it that there is nothing on the pan.
UNITS - button for changing weighing units.
TARE - tare function. Indicates the weight of the packaging itself. It is the difference between the total weight
of the goods with the packaging and the weight of the goods without packaging. The tare is used to remove
the weight of an item that should not be included in the overall weight measurement.
HOLD - Holding the weight result on the display.
3.3.1.
Calibration
The scale is factory calibrated. Do not recalibrate the scale, unless its accuracy is significantly different from
the norm.
Calibration:
Press and hold the ZERO and TARE keys at the same time, and then turn on the power using the ON/OFF
button. The display will show CAL followed by the A/D value. Press the TARE button, the display shows the
set calibration weight. Put the calibration weight on the pan, then press the TARE button. The display will
show "--------", then the A / D value. The calibration is complete.
3.3.2.
Internal settings, part 1
1. CAPU - unit of full load range in kg or lb.
2. CAP - full load range.
3. CALU = - kg or lb calibration unit.
4. CAL - calibration load value.
5. DIVS - scale.
6. ADC, ADC - select conversion number (18 ~ 20).