Position
Burner
Capacity - G20
2
AUX
1
AUX
min
Pressure
nom
(mbar)
max
Type of
Gas
MODEL
nr
nr
AUX
SR
FHNE 604 3G TC
1
FHNE 755 4G TC
1
FHNE 805 4G TC
1
(FM)
FHNE 1204 3G TC
1
(FM)
FHNE COR 4 3G TC
DC = Double Crown SR = Semi-Rapid R = Rapid AUX = Auxiliary C = Cast Iron Grid E = Enameled Grid
Power supply = 220-240 V; Frequency = 50-60 Hz; Power/current = 0.6 Watt
INSTALLATION
Installation and electrical/gas connection must
only be carried out by specialized and licensed
personnel. The manufacturer declines any
liability for injury to persons or damage to things due
to failure noncompliance with these provisions.
The gas connection must comply with the regulations
in force in the country at the time of installation.
Ensure that the device is connected directly to
Z
the mains socket. Ensure that no adapters, no
multi-sockets and no extension cables are used to
connect the device.
FHNE 604 3G TC / FHNE 755 4G TC / FHNE 805 4G TC / FHNE 805 4G TC FM /
FHNE 1204 3G TC / FHNE 1204 3G TC FM / FHNE COR4 3G TC
Rated
Injectors G20 -
20 mbar
0.095
0.78
0.095
0.72
17
20
25
G20 natural gas
MODELS' CONFIGURATION
nr
nr
nr
nr
nr
SR
R
R
DUAL
TC
DC
DC
2
1
2
1
1
1
2
1
1
1
1
2
1
1
Rated
Rated
Capacity -
Capacity -
G30
G31
73
73
73
73
20
25
28-30
37
35
45
GPL
G30 Butane - G31 Propane
N
Heat
Total
Total
Burners
Source
Rated
Rated
Capaci-
Capacity
ty G20
G30/
(m
/h)
G31
3
(g/h)
4
GAS
0.77
589
5
GAS 1.075
822
5
GAS
1.124
860
4
GAS
1
764
4
GAS
1.17
895
Cabinet requirements
This handbook refers to a class 3 built-in gas hob
and type Y for electric part.
The gas pipe must not come into contact with the
sides of any oven under the hob.
For fitted units, the components (plastic materials
and veneered wood) must be assembled with
heat-resistant adhesives (min. 100°C). Unsuitable
materials and adhesives can result in warping and
detachment.
The ventilation of rooms must be in compliance with
local regulation.
The kitchen element must allow sufficient room for
the electrical connections of the appliance.
– 7 –
Injectors
Rated
G30/G31
Power (kW)
28-30/37
mbar
0.50
1.00
0.50
1.00
Cat. II 2H3+
Air
Tot.
Tot.
Neccessa-
Installed
Installed
ry for
Gas
GPL
com-
Rated
Rated
bustion
Power
Power
(m
/h)
(kW)
(kW)
3
16.2
8.1
8.1
23
11.3
11.3
24
11.8
11.8
21.6
10.5
10.5
24.6
12.3
12.3
EN
Reduced
Power
(kW)
0.65
0.65
Weight
(net -
gross)
(kg)
10-11.5
14.2-15.8
12.6-14
21.9-24.3
20-24

Publicidad

loading

Este manual también es adecuado para:

Neptune fhne 755 4g tcNeptune fhne 805 4g tcNeptune fhne 805 4g tc fmNeptune fhne 1204 3g tcNeptune fhne 1204 3g tc fmNeptune fhne cor4 3g tc