Courtesy Light On/Off
Halt
Apartment block open
Foto
Safety function
Foto 1
Safety function
Foto 2
Safety function
Release and open
Release and close
Automatic opening active
Halt
program the required operating mode, se -
lecting in Table 1-E, 1-F (command con-
figuration" > "halt" > operating mode...)
already active and the command "timed cour-
tesy light" is sent again, the time programmed
in the function "courtesy light time" is reloaded.
Input configured as normally open.
This command enables activation and deacti-
vation of the courtesy light, programmable on
Output 1, 2 and 3. CAUTION! - The courtesy
light is switched off automatically if the relative
time interval elapses, as programmed in the
function "courtesy light time" (Control unit func-
tions > advanced parameters > output config-
uration > courtesy light time).
Input configured as normally open.
When this command is sent, the control unit
stops the manoeuvre in progress and activates
the application to execute the set operating
mode.
Input configured as normally closed..
When this command is sent the control unit
activates the application to complete the Ope -
ning manoeuvre until the position is rea ched as
set in the function "opening"(Control unit func-
tions > installation > positions > opening). Note
– This command is useful when using control
photocells or a magnetic detector loop.
Input configured as normally open.
When this command is sent during a closing
manoeuvre, the control unit stops the manoeu-
vre in progress and inverts travel (with an open-
ing manoeuvre).
Input configured as normally closed.
When this command is sent during a closing
manoeuvre, the control unit stops the manoeu-
vre in progress and inverts travel (with an open-
ing manoeuvre).
When this command is sent during an opening
manoeuvre, the control unit stops the manoeu-
vre in progress and when the command input
is terminated, resumes the manoeuvre.
Input configured as normally closed.
When this command is sent during an opening
manoeuvre, the control unit stops the manoeu-
vre in progress and inverts travel (with a closing
manoeuvre).
Input configured as normally closed.
When this command is sent, the control unit is
released (restoring normal operating status) and
activates the application to execute an Ope ning
manoeuvre.
Input configured as normally open..
When this command is sent, the control unit is
released (restoring normal operating status)
and activates the application to execute a Clo -
sing manoeuvre.
Input configured as normally open.
This command enables the activation or deac-
tivation of the function for bluebus control pho-
tocells and inputs configured in "apartment
block open" mode. Note – the factory setting
of this function is "active". For example, if this
function is active, when the control photocells