Descargar Imprimir esta página

Selco WF 116 Instrucciones De Uso página 22

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 51
Front control panel (WF 116 XP)
1
Power supply
Indicates that the equipment is connected to the mains
and is on.
2
General alarm
Indicates the possible intervention of protection devices
such as the temperature protection.
3
Power on
Indicates the presence of voltage on the equipment
outlet connections.
4, 5
7-segment display
Allows the general welding machine parameters to be
displayed during start-up, settings, current and voltage
readings, while welding, and encoding of the alarms.
6
Encoder key
Allows wire speed adjustment in manual MIG welding
and synergy correction in synergic MIG welding
Allows entry to set up, the selection and the setting of
the welding parameters.
7
Synergy
Allows selection of the manual MIG
process by setting the type of material to be weld-
ed.
Manual MIG process
Synergic MIG process, welding of carbon steel
Synergic MIG process, welding of stainless steel
Synergic MIG process, welding of aluminium
8
Wire diameter
In synergy, allows selection of the wire diameter used
(mm).
22
9
Welding methods
2 Step
In two step, pressing the button causes the gas to flow,
feeds voltage to the wire and makes it advance; when
it is released, the gas, the voltage and the wire feed are
turned off.
4 Step
In four step first pressure on the button causes the gas
to flow with a manual pre-gas time; releasing it activates
the voltage to the wire and its feed.
The following pressure on the button stops the wire and
causes the final process to start which brings the current
back to zero; finally releasing the button turns off the
gas flow.
Wire feed
Allows the manual wire feed without gas flow and with-
out the wire live.
Allows the insertion of the wire into the torch sheath
during the welding preparation phases.
3.2.1 Set up
Permits set up and adjustment of a series of additional parameters
for improved and more accurate control of the welding system.
Entry to set up: by pressing the encoder key for 3 sec. (the
central zero on the 7-segment display confirms entry).
Selection and adjustment of the required parameter: by
turning the encoder until displaying the numerical code relating
to that parameter. If the encoder key is pressed at this point,
the value set for the parameter selected can be displayed and
adjusted.
Exit from set up: to quit the "adjustment" section, press the
encoder again.
To exit the set up, go to parameter "O" (save and quit) and press
the encoder.
List of set up parameters
0
Save and quit
Allows you to save the changes and quit the set up.
1
Reset
Allows you to reset all the parameters to the default values.
.
90
Reset XE (Easy Mode)
It allows manual MIG welding with the adjustment of
the motor slope.
91
Reset XA (Advanced Mode)
or synergic MIG
It allows manual MIG and synergic MIG. "STANDARD
"synergic control entails automatic presetting of the ideal
welding parameters according to the selected position.
The settings are maintained during the different welding
stages.
The synergic value can be corrected as a percentage
according to the welder's requirements.
92
Reset XP (Professional Mode)
It allows manual MIG and synergic MIG). "INTERACTIVE
"synergic control entails automatic presetting of the ideal
welding parameters according to the selected position.
Synergic control stays active during the different welding
stages. The welding parameters are constantly controlled
and, if necessary, corrected according to precise analysis
of the electric arc!
The synergic value can be corrected as a percentage
according to the welder's requirements.
99
Reset
Allows you to re-set all the parameters to the default
values and restore the whole system to the conditions
predefined by SELCO.

Publicidad

loading

Este manual también es adecuado para:

Wf 116 xp