If the fitting connection has not been carried out yet, the next screenshot will prompt you
to carry it out.
When connecting the fitting, the screenshot on the right will appear showing the ohmic
resistance of the fitting to be welded.
After connecting the fitting, press ENTER
The welding time may change automatically according to the ambient temperature of the
working environment.
Press ENTER
. The screenshot shows a message reminding the operator that, before
welding, all the required preliminary actions must have been completed (scraping and
cleaning).
You will also be reminded that, in order to ensure good welding, an aligner must be used.
Press ENTER
to continue or ESCAPE
The following screenshot will show with the following summarised information:
After checking that all the data are correct, press the ENTER
If the welding cables have not been previously connected to the fitting, the display unit will
show an alarm message (error 31).
Press ESCAPE
to return to the main menu in Welding Mode.
If the connection has been completed correctly, a welding cycle begins and the following
screenshot will appear:
followed by:
to continue.
to return to the previous screenshot.
31
D
Fitting diameter
Time
Welding time
Voltage
Welding voltage
key to start welding.
Nominal Res.
Fitting rated resist. in Ohm
Meas. Res.
Fitting measured resiste. Ohm
Temp. Ext.
External temperature in °C/°F
Temp. Int.
Internal temperature in °C/°F
t.rem
Residual welding time in seconds
P
Power output in Watts
% welding progress
U
Welding voltage in Volts
E
Dissipated energy in Joules