A sound signal marks the end of the welding cycle and the screenshot on the right
appears. Press the ARROW UP key
to display a detailed welding report.
After disconnecting the welding cables from the fitting, the next screenshot will prompt you
to make a choice: press ENTER
(REPEAT) to show again the screenshot asking for
barcode scanning of the next fitting to be welded or press ESCAPE
(OTHER) to return
to the screenshot concerning the construction site data.
Memory download
After confirming all the general data about language, serial number, date and time,
operator code and construction site (by pressing the ENTER
key ), choose 'Download
USB Memory' from the next screenshot 'Operation'.
Now insert the USB key supplied with the machine into the USB port placed in the top
compartment of the machine.
Wait for 5 seconds before starting downloading the data by pressing the ENTER
key.
When the download is complete, you will see the screenshot shown on the right.
If the USB key has not been inserted correctly or if it is corrupt you will see the screenshot
on the right.
Memory erasing (welding reports)
Select Delete Memory from the main menu, press ENTER
and you will see the
screenshot on the right. Press again ENTER
to confirm the cancellation or ESCAPE
to return to the previous menu.