Notice of lnstallation
Requirements For Installation Position
■
Avoid places of inflammable or explosive gas leakage or where
there are strongly aggressive gases.
■
Avoid places subject to strong artificial electric/magnetic fields.
■
Avoid places subject to noise and resonance.
■
Avoid severe natural conditions (e.g. heavy lampblack, strong
sandy wind, direct sunshine or high temperature heat sources).
■
Avoid places within the reach of children.
■
Select where it is easy to perform service and repair and where
the ventilation good.
Installation environment inspection
■
Check nameplate of unit to make sure whether the refrigerant
is R290.
■
Check the floor space of the room. The space shall not be less
than usable space (12 m²) in the specification. The unit shall be
installed at a well-ventilated place.
■
Check the surrounding environment of installation site: R290 shall
not be installed in the enclosed reserved space of a building.
45