Menus
For installer
Menu
5 Installer setup System setup
Optional PCB connectivity
5.1
To connect to the external PCB
required for servicing.
• The external PCB is connected, the system will have following additional functions:
Control over 2 zones (including the swimming pool and the function to heat water in it).
1
External compressor switch.
2
External error signal.
3
SG ready control.
4
Demand control.
5
Heat-Cool SW
6
Zone & Sensor
5.2
To select the sensors and to
select either 1 zone or 2 zone
system.
Heater capacity
5.3
To reduce the heater power if
unnecessary.*
3 kW / 6 kW / 9 kW
* Options of kW vary depending
on the model.
Anti freezing
5.4
To activate or deactivate the
water freeze prevention when
the system is OFF
5.5
Base pan heater
To select whether or not
optional base pan heater is
connected.
* Type A - The base pan heater
activates only during
deice operation.
* Type B - The base pan heater
activates when outdoor
ambient temperature is
5 °C or lower.
14
Default Setting
Setting Options / Display
Yes
Zone
• After selecting 1
or 2 zone system,
proceed to the
selection of room or
swimming pool.
• If the swimming
pool is selected,
the temperature
2 Zone system
must be selected
for T temperature
between 2 °C ~
10 °C.
Sensor
* For room thermostat,
there is a further
selection of external
or internal.
3 kW
Yes
No
Yes
Set base pan heater
A
type*.