Descargar Imprimir esta página

Panasonic WH-ADC0309H3E5B Manual De Instrucciones página 19

Ocultar thumbs Ver también para WH-ADC0309H3E5B:

Publicidad

Idiomas disponibles

Idiomas disponibles

Menu
7 Installer setup Service setup
Pump maximum speed
7.1
To set the maximum speed of
the pump.
Pump down
7.2
To set the pump down
operation.
Default Setting
Setting Options / Display
Sterilization
Sterilization may be
more days of the
Monday
Sun / Mon / Tue /
Wed / Thu / Fri / Sat
Sterilization: Time
Time of the selected
day(s) of the week to
12:00
Sterilization: Boiling temp.
Set boiling
65 °C
temperatures for
sterilize the tank.
Sterilization: Ope. time (max)
Set sterilizing time
0:10
(in hours and minutes)
Setting the flow rate, max. duty and operation
ON/OFF of the pump.
Flow rate: XX:X L/min
Max. Duty: 0x40 ~ 0xFE,
Pump: ON/OFF/Air Purge
Pump down operation
ON
set for 1 or
week.
sterilize the tank
0:00 ~ 23:59
19

Publicidad

loading

Este manual también es adecuado para:

Wh-ud03he5-1Wh-ud05he5-1Wh-ud07he5-1Wh-ud09he5-1