Automatic repositioning
If the programmer blocks due to an encoder count error
reset
, the warning lights and indicator light will flash simultaneously for 2 seconds
and will then switch off for 10 seconds.
After the programmer has been in this condition for 3 minutes it will (after pre-flashing
for 10 seconds) automatically move the gate, slowly, to the completely closed position
(2 times as in the programming procedure) in order to recover the correct position.
DISPLAY MODE
Using the PROG button you can access the following functions in sequence:
- memorising the status of the dip-switches;
- display the status of the command and safety devices;
- display the number of manoeuvres;
The status of the security devices
CSP
are always shown on the display.
Memorising
the
DIP-SWITCH
displaying the firmware version (e.g. "V42")
The segments regarding the command status
(LED "ON" = command active) and safety status
(LED "ON" = safety device at rest) light up.
The number of manoeuvres appears on the
display. This number always remains visible until
you change the setting. Once 999999 has been
exceeded the lighting up of the decimal point on
the display equals 1 million + the six figure
number.
In the "test" mode (only activated when the motor
has stopped) it is possible to check the status of
the command and safety devices. The warning
lights
will
activate
"TA-TC-TAL-TD-Tb- FTCI-CSP" command is
received. In this mode you can activate serial line
communication by using the external program,
which is to be connected to the CSER connection
via cable (fig. 3). While communication is active
dashes will appear on the display; after 5 seconds
of inactivity you will be moved back to the "test"
mode. To return to the normal operating mode
press the "test" command again and wait for 10
seconds.
Limited opening setting from 1 to 9 metres (in the
example it has been set to 3 metres).
Each time "PROG" is pressed
the limited opening distance,
measured
in
metres,
increase (from 1 to 9).
10 seconds after the last
modification you will be
automatically moved out of
the mode and the selected
values will be saved (eg. 4)
All manuals and user guides at all-guides.com
or after a programmer
Tb
FTCI
,
and
settings
and
once,
each
time
a
PRESS
will
10 sec
PROG
At this point the programmer will function normally. To carry out automatic reposition-
ing without waiting for 3 minutes you may send a (TA, TC, TAL or TD) command to
the programmer. No commands will be accepted during repositioning but the security
devices will cut in and block all movement if they go into alarm.
• To interrupt the repositioning manoeuvre and delay it for another 3 minutes, press
the "PROG" button.
- access the "test" mode;
- set the limited opening distance;
- setting the current sensor level.
PRESS PROG
10 sec
PRESS PROG
10 sec
PRESS PROG
PRESS PROG
10 sec
PRESS PROG
PRESS PROG
Each time "PROG" is pressed
the number will increase (from 1
to 9).
10 seconds after the last
modification you will be automatically
moved out of the mode and the
selected values will be saved (eg. 4)
19
When the
("TA-TC-TD-TAL-Tb-FTCI-CSP")
inputs are activated the warning lights will light up.
5 sec
Connect the
programming device
PRESS PROG
(CSER) and activate it.
10 sec
Setting the current sensor.
1 = motor consumption + 1 amp
2 = motor consumption + 2 amps
3 = motor consumption + 3 amps
4 = motor consumption + 4 amps
5 = maximum torque ( max. 9 amps )
10 sec
PRESS PROG
10 sec