Descargar Imprimir esta página

Cardin Elettronica SL Serie Manual Del Usuario página 22

Ocultar thumbs Ver también para SL Serie:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

INDICATIONS ON THE DISPLAY (D1)
Start up display (shown for 2 seconds)
"860" = programmer model; " _42" = firmware version
Indicates the dip-switch setting memorisation stage
Alarm indications
System not programmed
You have to enter the programming mode to program the system.
Out of position
When carrying out an installation you will have to enter programming in order to program
the gate travel distances. During normal operation it indicates that the "automatic
repositioning" procedure is about to take place (see page 19). In this case any com-
mands received (TA, TC, TAL or TD) will automatically start this procedure.
Caution! The gate moves automatically without waiting for a command.
block during encoder programming
This happens when an N.C. contact is activated (Tb, FTCI, CSP) during encoder
programming or automatic repositioning. Once the passive state of the security
devices has been reset the gate will start moving again automatically. It also happens
if a blackout occurs during programming.
Safety test error
Check the condition of the safety devices and make sure that the alarm cuts in when
an obstacle interferes with the beam (the relative LED will switch off). In case of
anomalies replace the damaged safety device or bridge the contact and disactivate
the safety test (dip 7).
Motor feed error
This occurs when the programmer sends a command to the motor and nothing
happens (the motor doesn't move). Check the motor faston connections and the
condition of the fuses "F1" and "F3" and then give another opening or closing com-
mand. If the motor still doesn't move you are faced with either a mechanical problem
or a problem with the programmer.
-
Motor feed error
The gate movement direction is different from the encoder setting (eg. the gate moves
in the closing direction while the program is carrying out the opening stage). Check
the motor power supply connections and the setting of dip 8.
Encoder direction error
The gate movement direction is different from the encoder setting (eg. the gate moves
in the closing direction while the program is carrying out the opening stage). Check
the motor power supply connections and the setting of dip 8.
Current sensor error
When the gate is not moving this symbol means there is a problem with the current
sensor.
-
Motor error
These symbols mean there is a problem with the motor control relays.
All manuals and user guides at all-guides.com
Operational indications
22
Pause time programming
Automatic programming under way
Serial line (CSER) active (only for diagnostics)
Opening stage
block
Pause for automatic reclosing (if activated)
Closing stage
Current sensor updating (only during programming)
Opening + compensation sensor
Closing + compensation sensor
Test mode
battery mode with a fully charged battery
battery mode with an undercharged battery
block caused by a completely discharged battery

Publicidad

loading

Este manual también es adecuado para:

Sl 1524Sl 1524 sb