10
Technical data
Nominal Voltage
90 - 260 VAC 50/60 Hz
Output Current
Max. 16 A (up to 10 A possible over internal fuse)
Hybrid relay with safety-shutdown-relay (breaks heating
Power Switch
power circuit on failure)
Switching Cycles
> 2.5 million
Pt100, Pt1000, Nickel 120 (2, 3 or 4-wire) NTC 10k, NTC
Sensor Inputs
100k (2, 3 or 4-wire) Thermocouples K, J, E or N all
inputs potential-free with sensor break detection
Pt100, Pt1000: -120°C ... +850°C
NTC: -20°C ... +250°C
Ni120: -50°C ... +250°C
Adjustment Range
Type-K Thermo.: -200°C ... +1350°C
Type-J Thermo.: -210°C ... +1200°C
Type-E Thermo.: -200°C ... +1000°C
Type-N Thermo.: -200°C ... +1300°C
Controller Type
FAT (Fast-Adaptive-Tuning)
Thermal Protection
+ 85°C (Electronic Temperature, Self-Resetting)
151 x 125 x 60 mm Polycarbonate with non-detachable
Housing
clear cover UL 94-V0 Hinges for manual operation
LCD Graphic Display with 3-color LED for signaling of
Display
operation conditions
4-button keypad and menu control; Optional WRZF310
Operation
control unit (BH-310)
Potential-Free Signal Output
50 mA max. 45 V (potential free)
Ambient Temperature
-20°C to +50°C
Relative Humidity
< 90% noncondensing
Protection Standard
IP65 (cover closed and locked)
Weight
0.5 Kg
Protection Class
1
Input and Output connections (power and sensor) via
Connections (Standard)
cable glands and screw terminals
®
© BriskHeat
Corporation
BH-510 & BH-610 Operation
Manual
®
. All rights reserved.
11
11
Repair and maintenance
If the controller is damaged, please return the controller to us with an error description.
Maintenance intervals and Maintenance directives according to DGVU Vorschrift 3 apply.
If the device is dirty, turn power off, and clean it with a damp cloth. Heavy dirt may be cleaned with a
non-abrasive, solvent-free cleaning agent.
12
Disassembly and disposal
The device may only be disassembled when it is switched off, disconnected from the
mains and secured!
Electronic devices are recyclables and do not belong in the household waste! Dispose of
the product at the end of its service life in accordance with applicable legislation.
EU: Declaration of Conformity
Directives:
Directive 2014/35/EU Low Voltage Directive
Directive 2014/30/EU Electromagnetic Compatibility
Emission Immunity:
EN 61000-6-4:2011, EN 61000-6-2:2006
13
Warranty information
BriskHeat warrants to the original purchaser of this product for the period of eighteen (18) months from
date of shipment or twelve (12) months from date of installation, whichever comes first. BriskHeat's
obligation and the exclusive remedy under this warranty shall be limited to the repair or replacement, at
BriskHeat's option, of any parts of the product which may prove defective under prescribed use and
service following BriskHeat's examination, is determined by BriskHeat to be defective. The complete
details of the warranty can be found online at www.briskheat.com or by contacting us at 1-800-848-
7673 (toll free, U.S. / Canada) or 1-614-294-3376 (Worldwide).
Corporate Headquarters:
4800 Hilton Corporate Dr.
Columbus, OH 43232, U.S.A.
Toll Free: 800-848-7673
Phone: 614-294-3376
Fax: 614-294-3807
Email: bhtsales1@briskheat.com
®
© BriskHeat
Corporation
BH-510 & BH-610 Operation
Manual
Europe:
P.O. Box 420124
44275 Dortmund, Germany
®
. All rights reserved.
12