H
BATTERY CHARGING SETTINGS
NOTE: The charger features four independent output
channels, such that the charging progress of any one
channel is completely independent of the other three
channels. Each channel has a nominal output of 5 amps
and is current limited not to exceed 5 amps. An ERROR
or reverse connection on any one channel has no impact
on charging activity on any other channel.
All unit LEDs will light momentarily, then only the LEDs
corresponding to charging settings should stay lit. The
charger is now in Standby Mode. On any given channel,
Standby Mode is indicated by a blue AGM LED.
If an ERROR Indicator LED lights, disconnect from AC
power supply immediately and determine the cause of
the alarm. The POLARITY light indicates reverse polarity
connection error, while the ERROR light indicates the
detection of a battery fault, such as a shorted connection.
Charging a Battery:
1a. Bank 4 only. Choose an operating voltage (default
12V). To charge a 6V battery, push the voltage button
until the 6V LED is lit.
1b. Choose a battery type setting. To charge Standard
and Maintenance Free Flooded Acid batteries, push
the Battery Type button until the "STD" LED is lit. To
charge AGM batteries, push the Battery Type button
until the "AGM" LED is lit.
2. Press the "START/STOP" button and the charging
indicator LED will light. The charger will automatically
commence and complete the charging process. If you
press the "START/STOP" button at any point during
the charging sequence, the charger will stop charging
and return to Standby Mode.
BANKS 1-3
ERROR Indicator
Reverse Polarity Indicator
Standard Battery Type
Selected Indicator
OPERATING INSTRUCTIONS
START-STOP Button
START
STOP
STD
AGM
BANK 1
NOTE: If the ERROR LED lights, disconnect from AC
power immediately and determine the cause of the
alarm. See Additional Features for a list of conditions
that might cause this warning.
NOTE: The charger is designed to protect against
faults and shorts (see Battery Charger Features). If
the battery to be charged has a open circuit voltage of
less than 1V, the charger will indicate a fault. If, after
unplugging unit, checking connections and verifying
all settings, you determine the problem causing the
"fault" condition is battery voltage below 1V, you can
override the charger's protection by holding down the
"START/STOP" button for 3 seconds. The charger
will commence the charging sequence and, assuming
these are no other hindrances that caused the fault
indication, will complete the charging process and
automatically turn off when the battery has reached
full charge.
3. Once the battery has reached full charge, the Green
"Charge Complete" LED indicator will light solid green.
NOTE: The charger is designed for optimal energy
efficiency. Once the battery has reached full charge,
the display will enter power save mode. In this mode,
only the green Charge Complete indicator will blink
slowly. In this mode, any button press will wake
the display and the next button press will have its
intended effect.
4. When you are finished with the charging process,
press the START/STOP button to place the channel
in use into Standby Mode. Then, disconnect DC
leads from vehicle ground (if charging with battery in
vehicle) and battery in the reverse sequence of the
connection procedure.
Charge Complete Indicator
6 Volt LED
Solid - AGM Battery
Type Selected Indicator
Flashing - Channel
in Stand by Mode
BANK 4
START
STOP
6V
12V
STD
AGM
BANK 4
12 Volt LED

Publicidad